English
Language : 

BT136X-600E Datasheet, PDF (1/3 Pages) Continental Device India Limited – TRIAC
Continental Device India Limited
An ISO/TS 16949, ISO 9001 and ISO 14001 Certified Company
TRIAC
T2
T1
BT136X-600E
TO-220FP Fully Isolated
Plastic Package
G
For use in high bidirectional transient and blocking voltage applications, and for high thermal
cycling performance. Typical Applications include Motor Control, Industrial and Domestic
Lighting, Heating and Static Switching.
ABSOLUTE MAXIMUM RATINGS
PARAMETER
Repetitive Peak Off State Voltage
RMS on State Current
Non Repetitive Peak on State Current
l2t for Fusing
Repetitive Rate of Rise of On State
Current After Triggering
Peak Gate Current
Peak Gate Power
Average Gate Power
Storage Temperature
Operating Junction Temperature
SYMBOL
VDRM
IT (RMS)
ITSM
I2t
dlT/dt
IGM
PG M
PG (AV)
Tstg
Tj
VALUE
600
4.0
25
3.1
50
2.0
5.0
0.5
- 40 to 150
125
UNIT
V
A
A
A2s
A/µs
A
W
W
ºC
ºC
ELECTRICAL CHARACTERISTICS (TJ=25ºC unless specified otherwise)
PARAMETER
SYMBOL
TEST CONDITION
MIN
Gate Trigger Current
IGT
VD=12V, IT=0.1A
I
II
III
IV
Holding Current
IH
VD=12V, IGT=0.1A
Gate Trigger Voltage
VGT
VD=12V, IT=0.1A
On State Voltage
VT
IT=5A
Off State Leakage Current
ID
VDRM=600V
MAX UNIT
10
mA
10
mA
10
mA
25
mA
20
mA
1.5
V
1.7
V
0.5 mA
BT136X_600ERev021104E
Continental Device India Limited
Data Sheet
Page 1 of 3