Type HZC -55 ºC to +125 ºC
SMT Hybrid Polymer-Aluminum Electrolytic Capacitors
Load Life Test
Test
∆C at 120Hz
DF at 120 Hz
Apply the maximum rated voltage for 4,000 hrs at +125 °C with full rated ripple current. After
the test measure the capacitance, DF, DCL and ESR at +20 °C. Also measure the ESR at -40 °C and
100kHz.
Capacitance will be within ±30% of the initial measured value
DF will be ≤ 200% of the initial specified value
DCL after 2 minute charge Leakage current will be ≤ the initial specified value
ESR at 100kHz/+20 °C ESR will be ≤ 200% of the initial specified value
Max. ESR at 100kHz/-40 °C Case Code C : 2.0 Ω; Case Code D : 1.4 Ω; Case Code X : 0.8 Ω;
after Load Life test Case Code F : 0.4 Ω; Case Code G : 0.3 Ω
Shelf Life Test
Subject the capacitor to 1000 hrs at +125 °C without voltage. After the test, return the capacitor
Test
to room temperature for two hours and then apply rated voltage for 30 minutes. The after test
measurements for capacitance, DF, DCL and ESR at +20 °C will meet the following.
∆C at 120 Hz
Capacitance will be within ±30% of the initial measured value
DF at 120 Hz
DF will be ≤ 200% of the initial specified value
DCL after 2 minute charge Leakage current will be ≤ the initial specified value
ESR at 100Khz/+20 °C ESR will be ≤ 200% of the initial specified value
Moisture Resistance Test
Subject the capacitor to 2000 hrs at +85 °C/85%RH with rated voltage. After the test, return the
Test
capacitor to room temperature and humidity for two hours. The after test measurements for
capacitance, DF, DCL and ESR at +20 °C will meet the following.
∆C at 120 Hz
Capacitance will be within ±30% of the initial measured value
DF at 120 Hz
DF will be ≤ 200% of the initial specified value
DCL after 2 minute charge Leakage current will be ≤ the initial specified value
ESR at 100Khz/+20 °C ESR will be ≤ 200% of the initial specified value
Temperature Cycle Test
Subject the capacitor to 1000 cycles of temperature change from -55 °C to +125 °C using the
following sequence and durations.
Test
Step
1
2
3
4
Temperature
-55 ºC
+20 ºC
+125 ºC
+20 ºC
Time at Temperature
30 minutes
3 minutes max
30 minutes
3 minutes max
After the test, return the capacitor to +20°C for one to two hours before measurement. The after
test measurements for capacitance, DF, and DCL at +20 °C will meet the following;
∆C at 120 Hz
Capacitance will be within ±20% of the initial measured value
DF at 120 Hz
DF will be ≤ 200% of the initial specified value
DCL after 2 minute charge Leakage current will be ≤ the initial specified value
Appearance
No significant change in appearance