EDLR Datasheet, PDF (1/4 Pages) Cornell Dubilier Electronics – High discharge current | |||
|
Type EDLR, Long Life Electric Double Layer Ultracapacitor
Specifications
Operating Temperature Range
Rated Voltage Range
Capacitance Range
Type EDLR electric double layer supercapacitors offer high capacitance
values in a thru hole stacked coin type package. Primarily designed
for integrated circuit voltage backup, the capacitors can also be used
to deliver the initial power from batteries.
Highlights
- Long life
- High discharge current
- 85 ºC Operating temperature
â25 ºC to +85 ºC
3.6 Vdc to 5.5 Vdc
0.1 F to 1.0 F
Type
Capacitance (F)
Voltage (Vdc)
Capacitance Tolerance (%)
Max. Initial Internal Resistance (ohms at 1kHz)
RF
0.10
5.5
75
RD
RG
0.68
0.22
1.0
3.6
-20 to +80
20
50
20
Life, Moisture and Temperature Characteristics
After the following procedures have been performed, measure the capaci-
tance and internal resistance at +20 ºC.
Life Test:
Apply the max. operating voltage for 2000 h at +85 ºC
Capacitance Change ±30% of the initial measured value at +20 ºC
Internal Resistance ⤠2 times the initial specified value
Shelf Life:
Subject the capacitor to 2000 hours without voltage at +85 ºC.
Capacitance Change ±30% of the initial measured value at +20 ºC
Internal Resistance ⤠2 times the initial specified value
Moisture Resistance:
Subject the capacitor to 500 hours at +55 ºC at 90 to 95% RH without
voltage.
Capacitance Change ±10% of the initial measured value at +20 ºC
Internal Resistance meets the initial specified value
Soldering Heat Resistance:
Immerse the capacitor leads to within 2 mm of the capacitor body in
solder that is at a temperature of 260 ºC for 10 seconds.
Capacitance Change ±10% of the initial measured value at +20 ºC
Internal Resistance meets the initial specified value
Temperature Cycling
Stabilize the capacitor at each of the following temperatures for 1 hour in
sequence, and then measure the capacitance and internal resistance at
that temperature.
1. +20 ºC
2. -25 ºC
3. +20 ºC
4. +85 ºC
5. +20 ºC
Capacitance Change (at -25 ºC)
Internal resistance (at -25 ºC)
Capacitance Change (at +85 ºC)
Internal resistance (at +85 ºC)
Capacitance Change (Step 5 at +20 ºC)
Internal resistance (Step 5 at +20 ºC)
±30% of the initial measured value at +20 ºC
⤠5 times the initial measured value at +20 ºC
±30% of the initial measured value at +20 ºC
⤠4 times the initial measured value at +20 ºC
±10% of the initial measured value at +20 ºC
meets the initial specified value
RoHS Compliant without Exemptions
CDE Cornell Dubilier ⢠1605 E. Rodney French Blvd. ⢠New Bedford, MA 02744 ⢠Phone: (508)996-8561 ⢠Fax: (508)996-3830
|
▷ |