CAT5133
RELIABILITY CHARACTERISTICS
(Over recommended operating conditions unless otherwise stated.)
Symbol
NEND(1)
TDR(1)
Parameter
Endurance
Data Retention
Reference Test Method
MIL-STD-883, Test Method 1033
MIL-STD-883, Test Method 1008
Min
100,000
100
Notes:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
A.C. OPERATIONG CHARACTERISTICS
VCC = +2.5V to +6.0V, VH = VCC, VL = 0V, unless otherwise specified.
Symbol Parameter
Min
tCI
¯C¯S¯ to INC Setup
100
tDI
U/D to ¯IN¯¯C¯ Setup
50
tID
U/D to ¯IN¯¯C¯ Hold
100
tIL
¯IN¯¯C¯ LOW Period
250
tIH
¯IN¯¯C¯ HIGH Period
250
tIC
¯IN¯¯C¯ Inactive to ¯C¯S¯ Inactive
1
tCPH
¯C¯S¯ Deselect Time (NO STORE)
100
tCPH
¯C¯S¯ Deselect Time (STORE)
10
tIW
¯IN¯¯C¯ to VOUT Change
tCYC
¯IN¯¯C¯ Cycle Time
1
tR, tF(2)
tPU(2)
¯IN¯¯C¯ Input Rise and Fall Time
Power-up to Wiper Stable
tWR
Store Cycle
Typ(1)
1
5
A.C. TIMING
Max
Units
Cycles/Byte
Years
Max
Units
ns
ns
ns
ns
ns
μs
ns
ms
5
μs
μs
500
μs
1
ms
10
ms
Notes:
(1) Typical values are for TA=25ºC and nominal supply voltage.
(2) This parameter is periodically sampled and not 100% tested.
(3) MI in the A.C. Timing diagram refers to the minimum incremental change in the W output due to a change in the wiper position.
Doc. No. MD-2125 Rev. C
6
© Catalyst Semiconductor, Inc.