2 | LP-Series Illuminated Indicators - General Specifications
Electrical
Terminals
Lighted
Brass or copper/silver plate
3/16” (4.76mm) & 1/4” (6.3mm)
Quick Connect terminations
standard.
Incandescent - rated 10,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24VDC)
Physical
Seals
Base
Insert
Connector
Markings
Bracket
Insert, base & bracket are sealed.
Nylon 66 GF rated to 85°C with a
flammability rating of 94VO.
Polycarbonate rated at 100°C.
Nylon 66 rated at 85°C. Polarized
Over 1000 pad printed or laser
etched legends available
Nylon 66 GF rated to 85°C
Mounting Specifications
.867 [22.02]
1.020 [25.91]
3.055 [77.60]
1.734 [44.04]
TEST CUT
HOLE IN
ACTUAL
MATERIAL
MOUNTING HOLE
Panel Thickness Range
Acceptable Panel Thickness
.030 to .156 (.76mm to 3.96mm)
Recommended:
.030, .062, .093, .125 and .156
PADDLE STYLE ACTUATOR
Q.C. SELECTION GUIDE
COMPANY
SERIES
PACKARD
PART NO.
WIRE GAGE
AWG
MM 2
PACKARD
METRI-PACK
630 SERIES
TIN PLATED
BRASS
12084590
12052224
12015870
12015869
12020035
12052222
12
3.0
12
3.0
16-14
2.0-1.0
20-18
1.0-.80
22-18 (2 REQ'D) .80.-.50 (2 REQ'D)
20-22
.50-.35
Environmental
Environmental
IP67, representing an index of
protection as applied to electrical
equipment in accordance with IEC
529, BS 5490, DIN 400 50 &
NFC 20 010.
Corrosion Resistance Mixed Flowing Gas MFG Class III
per ASTM B-827 & B-845, Method
H, with 3 years exposure.
Operating Temperature -40°C to +85°C
Vibration 1
Per Mil-Std 202F, Method 204D Test
Condition A 0.06 DA or 10G’s 10-
500 Hz. Tested with VCH connector.
Test criteria - No loss of circuit
during test and pre and post test
contact resistance.
Vibration 2
Resonance search
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s max.
Random
24 Hz 0.06 PSD-Gsq/Hz
60 Hz 0.50
100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10µ
chatter.
Shock
Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with
VCH connector. Test criteria -
No loss of circuit during test, pre,
and post test contact resistance.
Salt Spray
Per Mil-Std 202F, Method 101D, Test
Condition A, 48 Hrs.
Thermal Shock
Per Mil-Std 202F, Method 107F, Test
Condition A, -55°C to 85°C. Test
criteria - pre and post test contact
resistance.
Moisture Resistance Per Mil-Std 202F, Method 106F, Test
Criteria - pre and post test contact
resistance.
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com