English
Language : 

WPC10R Datasheet, PDF (2/4 Pages) C&D Technologies – 2:1 WIDE INPUT RANGE DC/DC CONVERTER
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
MODEL
NOMINAL
INPUT
VOLTAGE
(VDC)
RATED
OUTPUT
VOLTAGE
(VDC)
OUTPUT CURRENT
MIN LOAD RATED LOAD
(mA)
(mA)
VOLTAGE REGULATION
LINE
(±)
LOAD
(±)
WPC10R24S03
24
WPC10R24S05
24
WPC10R24S12
24
WPC10R24S15
24
WPC10R24D05
24
WPC10R24D12
24
WPC10R24D15
24
3.3
300
3000
0.5%
1%
5
200
2000
0.5%
1%
12
83
833
0.5%
1%
15
67
666
0.5%
1%
±5
±100
±1000
0.5%
2%
±12
±42
±417
0.5%
2%
±15
±33
±333
0.5%
2%
WPC10R48S03
48
WPC10R48S05
48
WPC10R48S12
48
WPC10R48S15
48
WPC10R48D05
48
WPC10R48D12
48
WPC10R48D15
48
3.3
300
3000
0.5%
1%
5
200
2000
0.5%
1%
12
83
833
0.5%
1%
15
67
666
0.5%
1%
±5
±100
±1000
0.5%
2%
±12
±42
±417
0.5%
2%
±15
±33
±333
0.5%
2%
NOISE
(mVpp)
75
75
75
75
75
75
75
75
75
75
75
75
75
75
EFFICIENCY
(%)
75
77
78
79
77
78
79
77
79
80
81
79
80
81
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
CONDITIONS
MIN
INPUT
Voltage Range
18
VIN=34-75 for 3.3Vout
28
Reflected Ripple Current
TYP
24
48
20
ISOLATION
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficient
Line Regulation
Singles
Duals
Load Regulation
Singles
Duals
Ripple & Noise
GENERAL
Switching Frequency
MTTF per MIL-HDBK-217, Rev F
Ground Benign
Package Weight
TEMPERATURE
Specification (ambient)
Specification (case)
Operation (case)
Storage
60 Hz, 10 Seconds
V = 240VAC, 60Hz
ISO
Low Line to High Line
Min Load to Rated Load
BW = 5 Hz to 20 MHz
Circuit Stress Method,
TA = +25°C
1500
-25
-25
-40
-55
10
1500
100
±1
±0.02
±0.2
±0.2
±0.2
±0.5
350
933
35
MAX
36
75
50
UNITS
VDC
VDC
mAp-p
10
75
+71
+100
+100
+125
Vpk
GΩ
pF
mArms
Watts
%
%/°C
%
%
%
%
mVp-p
kHz
khr
g
°C
°C
°C
°C
Page 2