English
Language : 

HPR10XX Datasheet, PDF (2/4 Pages) C&D Technologies – 1.0 WATT UNREGULATED SIP DC/DC CONVERTER
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
NOMINAL
INPUT
VOLTAGE
RATED
OUTPUT
VOLTAGE
RATED
OUTPUT
CURRENT
INPUT CURRENT
NO LOAD
RATED LOAD
MODEL
(VDC)
(VDC)
(mA)
(mA)
(mA)
REFLECTED
RIPPLE
CURRENT
(mAp-p)
EFFICIENCY
(%)
HPR1000
5
5
200
33
290
8
68
HPR1001
5
12
83
33
290
8
69
HPR1002
5
15
67
33
285
8
70
HPR1003
5
±5
±100
33
285
8
70
HPR1004
5
±12
±42
33
285
8
70
HPR1005
5
±15
±34
33
285
8
70
HPR1006
12
5
200
18
110
10
70
HPR1007
12
12
83
18
107
10
71
HPR1008
12
15
67
18
107
10
71
HPR1009
12
±5
±100
18
107
10
71
HPR1010
12
±12
±42
18
107
10
71
HPR1011
12
±15
±34
18
107
10
71
HPR1012
15
5
200
15
96
10
70
HPR1013
15
12
83
15
94
10
70
HPR1014
15
15
67
15
94
10
71
HPR1015
HPR1016
15
±12
±42
15
94
10
71
HPR1017
15
±15
±34
15
94
10
71
HPR1018
24
5
200
12
60
15
71
HPR1019
24
12
83
12
60
15
71
HPR1020
24
15
67
12
58
15
72
HPR1021
24
±5
±100
12
58
15
72
HPR1022
24
±12
±42
12
58
15
72
HPR1023
24
±15
±34
12
58
15
72
Note: Other input to output voltages may be available. Please contact factory.
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
Voltage Rise Time
4.5
5
5.5
VDC
10.8
12
13.2
VDC
13.5
15
16.5
VDC
21.6
24
26.4
VDC
See Typical Performance Curves & Application Notes: "Capacitive Loading Effects on Start-Up of DC/DC Converters"
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Ripple & Noise
Voltage
Temperature Coefficent
60 Hz, 10 Seconds
V = 240VAC, 60Hz
ISO
1000
1000
10
25
2
1.0
Rated Load, Nominal VIN
BW = DC to 10MHz
BW =10Hz to 2MHz
30
1mA Load, VOUT = 5V
1mA Load, V = 12V
OUT
1mA Load, VOUT = 15V
.01
VDC
Vpk
GΩ
100
pF
8.5
µArms
W
±5
%
100
mVp-p
mVrms
7
VDC
15
VDC
18
VDC
%/Deg C
REGULATION
Line Regulation
Load Regulation (5V out only)
Load Regulation (All other Models)
High Line to Low Line
Rated Load to 1mA Load
Rated Load to 1mA Load
1
%/%Vin
10
%
3
%
GENERAL
Switching Frequency
Frequency Change
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
Fixed Ground
Naval Sheltered
Airborne Uninhabited Fighter
Over Line and Load
Circuit Stress Method
TA = +25°C
TA = +35°C
TA = +35°C
TA = +35°C
170
kHz
24
%
2
g
3.8
MHr
1.4
MHr
685
kHr
211
kHr
TEMPERATURE
Specification
Storage
-25
+25
+65
°C
-50
+110
°C
* For demonstrated MTTF results reference Reliability Report HPR105
Page 2
HPR10XX REV C 9/98