English
Language : 

VRK81B080CS Datasheet, PDF (1/4 Pages) C&D Technologies – Programmable, 80A Single Output DC/DC Converter
VRK81B080CS
Programmable, 80A Single Output DC/DC Converter
FEATURES
Meets AMD K8 requirements
DAC Programmable output voltage
Power good output
Differential remote sense
Remote enable
Supervisory functions
Latch off overcurrent
Short circuit protection
Tri-state output when disabled
Dynamic VID capability
SMBus temperature monitor
DESCRIPTION
VRK81B080CS is designed to meet the fast load
transients required by AMD 64-bit processors
and is fully compliant with the latest AMD64™
processor power specifications. High efficiency of
85% at full load for reduced power dissipation to
simplify system thermal management. Packaged
in a compact design, VRK81B080CU is ideal for use
in a wide variety of server applications.
SELECTION GUIDE
Order Code
VRK81B080CS
Input Voltage
V (NOM.)
12
Output Voltage
V
0.8-1.55
INPUT CHARACTERISTICS
Parameter
Conditions1
MIN.
Input voltage operating range
10.2
Turn-on threshold
6.5
Under voltage lockout
Turn-off threshold
5.4
Hysteresis voltage
0.7
Maximum input current
Typical: 80A, 1.4VID, VIN = 12V
Max: 80A, 1.55VID, VIN = 12V
No-load input current
Enable state, no load
100
Disabled input current
Disabled state
10
On state range
0.8
Enable - positive logic
Off state range
-0.3
OUTPUT CHARACTERISTICS
Parameter
Conditions1
Voltage set point
5-Bit DAC controlled
Line regulation
Load regulation
Voltage total regulation DC
Ripple & noise 2
20MHz bandwidth, using
recommended output capacitors
Current operating range
Efficiency
IO = 80A, VID = 1.325V
Turn-on time
Recommended bulk output
capacitance
VIN present: enable to 90% VOUT
560μF, 4V alum poly
10μF, 1206 X7R ceramic
MIN.
0.800
-5
VID-50mV
0
83
GENERAL CHARACTERISTICS
Parameter
Conditions1
MIN.
Semiconductor junction
temperature
Package rated to 150ºC
Material flammability
MTBF
Switching frequency
UL 94V-0
Calculated (RAC PRISM)
Per phase
TEMPERATURE CHARACTERISTICS
Parameter
Conditions1
MIN.
Storage temperature range Non-condensing
-40
Operating temperature
range
See derating graph
0
Output
Current
A
80
Efficiency
% (TYP.)
85
TYP.
MAX. Units
12.0
13.2
6.9
7.3
V
6.0
6.6
0.9
1.1
11
A
13
200
400
mA
20
50
5
V
0.4
TYP.
MAX. Units
1.55
V
0
5.0
mV
0.6
mΩ
VID+50mV V
8.4
mVp-p
80
A
85
%
50
mS
8
EA
25
EA
TYP.
1.303
300
MAX.
115
Units
ºC
x106 Hrs
KHz
TYP.
MAX. Units
70
ºC
60
PROTECTION CHARACTERISTICS
Parameter
Conditions1
Output overcurrent
shutdown
Latching
Overvoltage Indication,
CBOUT
VOUT
MIN.
TYP.
MAX.
85
120
2.1
1. VIN = 12VDC, TA = 25ºC, Airflow = 400LFM unless otherwise noted.
2. Output ripple voltage is specified when measured with recommended capacitance at the output of the converter.
Units
A
V
www.cd4power.com
ODC_VRK81B080CS.1 Page 1 of 4