English
Language : 

TPS_PX500 Datasheet, PDF (1/4 Pages) C&D Technologies – AC/DC 500W Multiple Output Power Supply
PX500 Series
AC/DC 500W Multiple Output Power Supply
SELECTION GUIDE
Model Number
Output 1
Output 2
Output 3
Output 4
PX500U3ABFHPHM
PX500U3BBFHPHM
PX500U4CBFHPHM
5V@80A
5V@80A
5V@80A
12V@12A
15V@12A
12V@12A
12V@12A
15V@12A
12V@12A
--
--
5V@4A
PX500U4CBFHPHMC
5V@80A
12V@12A
12V@12A
5V@4A
FEATURES
n Industry Standard 2"x5"x10" Package
PX500U4EBFHPHM
PX500U4HBFHPHM
PX500U4HBFHPHMC
5V@80A
5V@80A
5V@80A
12V@12A
12V@12A
12V@12A
12V@12A
12V@12A
12V@12A
n 500W Power at 0-50ºC
n Active Power Factor Correction
n Efficiency up to 75%
n Power Fail Warning Signal
n 80A Main Output
n Remote Sense on Main Output
n Remote Inhibit Control
n Class B conducted EMI Performance
PX500U4HBVHPHM
CT PX500U4HBVHPHMC
U PX500U4LBFHPHM
PROD odel PX500U4LBFHPHMC
5V@80A
5V@80A
5V@80A
5V@80A
BSOLETfEor Replacement M INPUT CHARACTERISTICS
OContact Factory Parameter
Input Operating Voltage
Input Frequency
12V@12A
12V@12A
12V@12A
12V@12A
12V@12A
12V@12A
12V@12A
12V@12A
Conditions Min
90
47
n Global 90-264VAC Input
Input Current
12V@4A
5.2V@10A
5.2V@10A
5.2V@10A
5.2V@10A
3.3V@10A
3.3V@10A
Typ
Max
264
63
7.0
n Active Current Sharing on Output V1
n RoHS Compliant
DESCRIPTION
The PX500 is a family of 500W, multiple-output
power supplies developed for a broad range of
applications. All outputs are fully isolated and
regulated for either positive or negative ground
reference. The outputs can also be connected in
series to develop higher voltages or in parallel to
develop higher currents.
The two-switch forward topology used in the
PX500 supplies has been field-proven for high
reliability. The mag-amp post-regulators used
on the auxiliary outputs will support high peak
currents.
With a global input of 90-264VAC, safety agency
approvals to UL1950, CSA C22.2 No. 234-M90,
and EN60950, EMI compliance to Class B FCC
Part 15, the PX500 was designed with globally-
deployed product applications in mind.
The PX500 is available in various output voltage/
current configurations and with various cover op-
tions. Additional features include remote sense
compensation, a power fail warning signal, as
well as output inhibit. Several models of the
PX500 are also available with RoHS compliance.
ISO9001
CERTIFIED
Power Factor
Inrush Current
OUTPUT CHARACTERISTICS
Parameter
Output Power
Temperature Coefficient
Voltage Regulation
Minimum Load
Minimum Load
PARD (Vo)
Output Voltage Adjustment
Transient Excursion (Vo)
Transient Recovery (Vo)
Output Holdup Time
Isolation, Pri-Sec
Isolation, Pri-Chassis
Isolation, Sec-Chassis
Current Share Tolerance
240Vac
120Vac
0.99
70
30
Conditions
All line & environmental
After 30min warm up
Line
Load
Cross
V1
V2, V3, V4
20MHz bandwidth
All outputs
25% load step, 1A/μsec
max slew
25% load step, 1A/μsec
max slew
Full load, low line
Output V1; Io>25%
Min Typ Max
500
0.02
-0.1
+0.1
-0.5
+0.5
-0.1
+0.1
4
0
1
-5
+5
-3
+3
400
20
3
1.5
500
10
Remote Sense Comp. (Vo)
1000
NA
NA
NA
Yes
NA
NA
Yes
NA
Yes
NA
Yes
Units
Vac
Hz
Arms
Apk
Apk
Units
W
%/ºC
%Vo
%Vo
%Vo
A
A
%Vnom
%Vnom
%Vo
μsec
msec
kVac
kVac
Vac
%
mV
www.cd4power.com