English
Language : 

S016-1220120-FB Datasheet, PDF (1/9 Pages) C&D Technologies – DC/DC Converter 12V Input, 1.2 - 5.0V Adjustable Output, 16A or 45W
DC/DDCC/DCCoCnovnevretreterr
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
12V Input, 1.2 - 5.0V Adjustable Output, 16A or 45W
Features
✓ Output Current up to 16A or 45W max
✓ 12V +5/-10% input
✓ Load Regulation ±0.5%
✓ Factory set to 1.2V Output with Output Trim up to 5.0V
✓ High Efficiency to 90%
✓ Back Bias Protection
✓ Short Circuit Protection
✓ MTBF 4.2 million hours
✓ Can sink 8A current, maintaining Output Regulation
This unit is not fuse protected. User is responsible for providing system protection.
Consult factory for application information.
Specifications *
Input Specifications
Input voltage range
External input capacitor
Output Specifications
Standard output voltages
and output current
Load regulation
Line regulation
External output capacitor
Short circuit protection
General Specifications
Enable **
Efficiency
Isolation
Switching frequency
Approvals and Standards
Protection
Operating Temperature ***
Storage Temperature
Weight
MTBF
S016-12
12.0V +5/-10%
Input capacitor capable
of ripple current
Measured at +Vin pin
See ripple current curve on pg 6 and Input and Output
Capacitance table on pg 8
1.2V, 16A
1.25V, 16A
1.5V, 16A
1.8V, 16A
2.5V, 13A
3.3V, 11A
5.0V, 9A
±0.5%
±0.4%
820µF OSCON or equiv-
alent with ESR < 12mΩ
200% of maximum rated
current
Regulation range is ± 3% including output voltage set
point, line regulation and load regulation over the operat-
ing temperature range.
See DC Voltage Regulation table on pg 6 for trimming to
different voltages
0 to 16A load
12.0V input voltage range
See also Input and Output Capacitance table on pg 8
Autorecovery
ON-high / OFF-low
90% - 69%
Non-isolated
360kHz
UL 94V-0
Fusing
10°C to 50°C
-40°C to 70°C
0.25 oz
3.6 million hours
See efficiency curves on pg 4
Fixed
Unit is not fused.
See also derating curves
Non-condensing
Per RAC PRISM at 50°C ambient and 300 LFM
* All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
** Pull below 0.35V to disable the SIP; pull above 2.4V (do not exceed 5.5V) to enable the SIP.
*** The output capacitors must meet the max ESR <12 mΩ requirement over the operating temperature range.
1150 Eglinton Avenue East
Toronto, Ontario M3C 1H7
1-866-740-1232
S016_084-S016-00_RevG_Jan12-2005.fm
www.cdtechno-cps.com
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
1 of 9