English
Language : 

NMR Datasheet, PDF (1/2 Pages) C&D Technologies – Isolated 1W Single Output DC-DC Converters
NMR SERIES
Isolated 1W Single Output DC-DC Converters
SELECTION GUIDE
Nominal
Input Output Output Input Current
Voltage Voltage Current at Rated Load
Order Code (V)
(V)
(mA)
(mA)
(%)
NMR100
5
5
200
290
69
MTTF1
(pF)
kHrs
28
1322
FEATURES
s Wide Temperature Performance at
Full 1 Watt Load, –40°C to 85°C
s Industry Standard Pinout
s 1kVDC Isolation
s Efficiency to 79%
s Power Density up to 0.90W/cm3
s 5V & 12V Input
s 5V, 12V & 15V Output
s Footprint of 1.17cm2
s UL 94V-0 Package Material
s No Heatsink Required
s Internal SMD Construction
s Toroidal Magnetics
s Fully Encapsulated
s No External Components Required
s MTTF up to 1.6 Million Hours
s Custom Solutions Available
s No Electrolytic or Tantalum
Capacitors
DESCRIPTION
The NMR series of industrial temperature
range DC-DC converters are the standard
building blocks for on-board distributed
power systems. They are ideally suited for
providing single rail supplies on primarily
digital boards with the added benefit of
galvanic isolation to reduce switching noise.
Surface mount technology and advanced
packaging materials produce rugged reliable
performance over an extended temperature
range from –40°C to 85°C.
NMR101
5
12
83
260
77
33
235
NMR102
5
15
67
253
79
40
127
NMR106
12
5
200
121
69
36
515
NMR107
12
12
83
110
76
58
184
NMR108
12
15
67
110
76
56
111
When operated with additional external load capacitance the rise time of the input voltage will determine the
maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the
greater the maximum value of the additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
Parameter
Conditions
MIN TYP MAX Units
Voltage Range Continuous operation, 5V input types
4.5
5
5.5
Continuous operation, 12V input types 10.8 12 13.2
V
Reflected Ripple Current
40
60 mA p-p
OUTPUT CHARACTERISTICS
Parameter
Conditions
MIN
Rated Power2 TA= –40°C to 85°C
Voltage Set
Point Accuracy
See tolerance envelope
Line Regulation High VIN to low VIN
10% load to rated load, 5V output types
Load Regulation 10% load to rated load, 12V output types
10% load to rated load, 15V output types
Ripple & Noise BW=DC to 20MHz
TYP
1.0
12.5
6.9
6.5
30
MAX
1.0
Units
W
1.2
13.4
7.7
7.5
50
%/%
%
mV p-p
ABSOLUTE MAXIMUM RATINGS
Short-circuit duration3
Internal power dissipation
Lead temperature 1.5mm from case for 10 seconds
Input voltage VIN, NME05 types
Input voltage VIN, NME12 types
1 second
550mW
300°C
7V
15V
www.dc-dc.com
1 Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2 See derating curve
3 Supply voltage must be discontinued at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.