English
Language : 

NDY Datasheet, PDF (1/3 Pages) C&D Technologies – Isolated 3W Wide Input DC-DC Converters
NDY SERIES
Isolated 3W Wide Input DC/DC Converters
SELECTION GUIDE
FEATURES
■ Industry Standard Footprint
■ Single Isolated Output
■ Short Circuit Protection
■ Operating Temperature Range
-40°C to +85°C
■ Low Profile 24 Pin Case
■ Efficiency to 82%
■ Power Density 0.90W/cm3
■ 2:1 Wide Input Range
■ 5V, 12V, 24V & 48V Input
■ 3.3V, 5V, 9V, 12V & 15V Output
■ Footprint 4.73cm2
■ UL 94V-0 Package Materials
■ No Heatsink Required
■ Internal SMD Construction
■ Fully Encapsulated
■ Lead Free Compatible
DESCRIPTION
The NDY series is a range of low profile
DC/DC converters offering a single regulated
output over a 2:1 input voltage range. All
parts deliver 3W output power up to 85°C
without heatsinking, except the 4.5V to 9V
input voltage range which should be derated
to 2W at the lower input voltage. A flyback
oscillator design with isolated feedback is
used to give regulation over the full operating
range of 25% to 100% of full load. It is
strongly recommended that external
capacitors be used on input and output to
guarantee performance over full load and
input voltage range (see recommended filter
circuit for values). The plastic case and
encapsulant materials are rated to UL 94V-0
and the connection pins are formed from a
tin plated alloy 42 leadframe.
Nominal Rated
Input Output
Output Current 4
Voltage Voltage Min Load Full Load
Input
Current
Full Load
MTTF3
Order Code (V)
(V)
(mA)
(mA)
(mA)
(%) (pF) kHrs
NDY0505
5
5 100 -150 400- 600
615
66 40 1939
NDY0509
5
9
55-83 222-333
563
72 52 1926
NDY0512
5
12
42-62 166-250
548
71 43 1907
NDY0515
5
15
33-50 133-200
533
73 44 1924
NDY1205
12
5
150
600
362
71 36 1928
NDY1209
12
9
83
333
320
78 52 1916
NDY1212
12
12
62
250
316
78 44 1897
NDY1215
12
15
50
200
308
79 47 1914
NDY2403
24
3.3
227
909
178
70 30 1671
NDY2405
24
5
150
600
174
70 36 1673
NDY2409
24
9
83
333
156
78 52 1663
NDY2412
24
12
62
250
154
80 44 1644
NDY2415
24
15
50
200
150
82 54 1657
NDY4803
48
3.3
227
909
87
71 30 1676
NDY4805
48
5
150
600
87
73 35 1668
NDY4809
48
9
83
333
78
80 52 1663
NDY4812
48
12
62
250
77
81 44 1648
NDY4815
48
15
50
200
76
81 53 1661
INPUT CHARACTERISTICS
Parameter
Voltage Range
Reflected1
Ripple
Current
Conditions
All NDY05XX
All NDY12XX
All NDY24XX
All NDY48XX
NDY24032
NDY48032
All NDY05XX
All NDY12XX
All other NDY24XX
All other NDY48XX
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Input voltage 05 types
Input voltage 12 types
Input voltage 24 types
Input voltage 48 types
Lead temperature 1.5mm from case for 10 seconds
Minimum Load
Internal Dissipation
MIN TYP MAX Units
4.5
5
9
9
18
12
24
18
36
VDC
36
48
72
180 360
140 290
400 500 mA p-p
150 170
290 360
100 127
continuous
10V
20V
40V
80V
300°C
25% of rated load
1.7W
www.cdpoweronline.com
1 Measured at full load with external input/output capacitors, refer to filter circuit 1.
2 For lower ripple refer to filter circuit 2.
3 Calculated using MIL-HDBK-217F with nominal input voltage at full load.
4 Refer to power derating graph.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.