NDL SERIES
Isolated 2W Wide Input Single Output DC-DC Converters
SELECTION GUIDE
FEATURES
s 2:1 Wide Range Voltage Input
s Continuous Short Circuit Protection
with Current Foldback
s Operating Temperature Range
–40°C to 85°C
s 0.5% Regulation
s 1kVDC Isolation
s Efficiency to 83%
s 5V, 12V, 24V & 48V Nominal Input
s 5V, 9V, 12V & 15V Output
s Power Density 0.9W/cm3
s External Control
s No Electrolytic Capacitors
s Low Noise
s Fully Encapsulated
DESCRIPTION
The NDL series is a range of high
performance miniature DC-DC converters
having regulated outputs over the wide
temperature range of –40°C to 85°C. The
input voltage range is 2:1 with the output
power at 2 watts and the input to output
isolation is 1kVDC. Continuous short circuit
protection, external control and extremely
small SIP packaging provide state of the art
functionality. The use of ceramic capacitors
and a ceramic substrate, with a tough chip
and wire bonded MOSFET power transistor
die and SMD construction, provide genuine
high reliability. Nominal input voltages of
5,12,24 and 48V with output voltages of
5,9,12 and 15V are available as standard
with custom parts on request. The plastic case
is rated to UL 94V-0 with encapsulant to UL
94V-1. Connection pins are phosphor bronze
with a 60/40 tin lead solder dipped finish.
www.dc-dc.com
Nominal Rated
Input Output
Output Current 1
Voltage Voltage Min Load3 Full Load
Input
Current2
Full Load
MTTF4
Order Code (V)
(V)
(mA)
(mA)
(mA)
(%) (pF) kHrs
NDL0505S
5
5
100
400
606
66 26 2015
NDL0509S
5
9
55
222
558
71 27 1998
NDL0512S
5
12
42
167
559
71 26 1980
NDL0515S
5
15
33
134
549
73 27 1965
NDL1205S
12
5
100
400
228
73 39 1994
NDL1209S
12
9
55
222
211
79 38 1981
NDL1212S
12
12
42
167
208
80 47 1961
NDL1215S
12
15
33
134
206
81 47 1947
NDL2405S
24
5
100
400
112
74 37 1722
NDL2409S
24
9
55
222
102
81 40 1711
NDL2412S
24
12
42
167
100
81 51 1696
NDL2415S
24
15
33
134
100
83 58 1685
NDL4805S
48
5
100
400
57
73 39 1719
NDL4809S
48
9
55
222
52
80 40 1709
NDL4812S
48
12
42
167
51
81 53 1694
NDL4815S
48
15
33
134
51
82 65 1683
INPUT CHARACTERISTICS
Parameter
Conditions
All NDL05 Types
Voltage Range
All NDL12 Types
All NDL24 Types
Reflected
Ripple
Current
All NDL48 Types
All NDL05 types when 100µF at input
All NDL12 types when 100µF at input
All NDL24 types when 10µF at input
All NDL48 types when 10µF at input
MIN TYP MAX Units
4.5
5
9
9
18
12
24
18
36
VDC
36
48
72
250
300
150
380
mA p-p
140 170
OUTPUT CHARACTERISTICS
Parameter
Voltage Set
Point Accuracy
Conditions5
All NDL 05/12 types with external
input/output capacitors
All NDL 24/48 types with external
input/output capacitors
Line Regulation
All NDL 05/12 types, Low line to high line,
With external input/output capacitors
All NDL 24/48 types, Low line to high line,
With external input/output capacitors
All NDL 05/12 types, Minimum load to rated load,
Load Regulation
With external input/output capacitors
All NDL 24/48 types, Minimum load to rated load,
With external input/output capacitors
Ripple
B/W=20Hz to 300kHz
With external input/output capacitors
All NDL 05 types, B/W=DC to 100MHz
With external input/output capacitors
Noise
All NDL 12 types, B/W=DC to 100MHz
With external input/output capacitors
All NDL 24/48 types, B/W=DC to 100MHz
With external input/output capacitors
Shutdown Power VIN nominal
TYP
±1
±2
0.05
0.04
0.2
0.2
5
20
110
50
MAX
±5
±5
0.5
0.4
0.75
0.75
10
35
170
100
2.8
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Lead temperature 1.5mm from case for 10 seconds
Control pin input current
Input voltage 05 types
Input voltage 12 types
Input voltage 24 types
Input voltage 48 types
continuous
300°C
10mA
10V
20V
40V
80V
1 Refer to power derating graph for operation of 5V input types at 4.5 to 6V.
2 Measured at full load with external input/output capacitors, refer to recommended test circuit.
3 A lower load condition is entirely safe but higher levels of output ripple will be experienced.
4 Calculated using MIL-HDBK-217F with nominal input voltage at full load.
5 Refer to recommended test circuit for external input/output capacitors.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Units
%
%
%
mV rms
mV p-p
mW