English
Language : 

78250 Datasheet, PDF (1/2 Pages) C&D Technologies – Converter Transformers
78250 SERIES
Converter Transformers
SELECTION GUIDE 78250/78250M
Parameter
Conditions
Primary Inductance, LP
10kHz, 100mV
Leakage Inductance, LL
100kHz, 100mV
Interwinding Capacitance, C WW 100kHz, 100mV
D.C. Resistance, RDC
<0.1VDC
FEATURES
s Maxim Compatible
s Isolation to 4kV
s Surface Mount Options
s Toroidal Construction
s Standard Pinout
s UL 94V-0 Package Material
s Fully Encapsulated
s Low Profile
s Industrial Temperature Range
DESCRIPTION
The 78250 series of converter transformers
are specifically designed for use with Maxim
chipsets to provide isolated RS232 interfaces.
Carefully controlled turns ratios ensur e
consistent performance whilst a toroidal
construction minimises EMI. The surface
mount devices are fully compatible with
CECC00802 to 280°C which allows them to
be placed and reflowed with IC’s thus
reducing time and cost in production.
Volt-time Product, ET
5kHz, 5V
SELECTION GUIDE 78250V/78250MV
Parameter
Conditions
Primary Inductance, LP
10kHz, 100mV
Leakage Inductance, LL
100kHz, 100mV
Interwinding Capacitance, C WW 100kHz, 100mV
D.C. Resistance, RDC
<0.1VDC
Volt-time Product, ET
5kHz, 5V
ABSOLUTE MAXIMUM RATINGS
Operating free air temperature range
Storage temperature range
Lead Temperature 1.5mm from case for 10 seconds
Peak current IPK
Isolation voltage 78250(M) (flash tested for 1 second)
Isolation voltage 78250V(M) (flash tested for 1 second)
All specifications typical at TA=25°C.
MIN TYP MAX Units
1.0 2.0 2.5 mH
2.0 3.0 µH
69 90 pF
1.0 2.0 Ω
50
Vµs
MIN TYP MAX Units
1.0 2.0 2.5 mH
35 40 µH
9
12 pF
1.4 1.8 Ω
50
Vµs
–40°C to 85°C
–50°C to 125°C
300°C
300mA
1500Vrms
4000Vrms