FEATURES:
 6000 VDC Isolation
 Low Profile DIP 16 Package
 Industry Standard Pinout
 MTBF>3,500,000 hours
Click on Series name for product info on aimtec.com
Series AM2B-NZ
2 Watt | DC-DC Converter
 Unregulated Single Output Models
 Operating Temperature: -40°C to +105°C
 High Efficiency up to 81%
 RoHS Compliant
Models
Single output
Model
Input Voltage Output Voltage Output Current
(V)
(V)
max (mA)
Isolation
(VDC)
Efficiency
(%)
AM2B-0505SH60-NZ
4.5-5.5
5
400
6000
77
AM2B-0512SH60-NZ
4.5-5.5
12
167
6000
81
AM2B-0515SH60-NZ
4.5-5.5
15
133
6000
80
AM2B-1205SH60-NZ
10.8-13.2
5
400
6000
77
*AM2B-1215SH60-NZ
10.8-13.2
15
133
6000
81
AM2B-2405SH60-NZ
21.6-26.4
5
400
6000
78
AM2B-2415SH60-NZ
21.6-26.4
15
133
6000
80
*Not recommended for new design
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
5
12
24
Typical
4.5-5.5
10.8-13.2
21.6-26.4
Maximum
Units
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Capacitance
Resistance
Conditions
60 sec
500VDC
Typical
10
>1000
Rated
6000
Units
VDC
pF
MOhm
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
See Tolerance Graph
±5
%
Short circuit protection
Continuous
Short Circuit restart
Auto Recovery
Line voltage regulation
For a 1% change of Vin
±1.2
%
Load voltage regulation
Temperature coefficient
From 10% load to 100% load
At 100% load
12
±0.03
%
%/oC
Ripple & Noise*
20MHz Bandwidth
150
mV p-p
Minimum load current**
10
% of Max
* Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick &
POL DC-DC Converters” available at www.aimtec.com
** If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
www.aimtec.com
F 051e R12.G
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)