English
Language : 

PACR6G Datasheet, PDF (2/3 Pages) California Micro Devices Corp – EMI/RFIT-FILTER
CALIFORNIA MICRO DEVICES
PACR6G
Signal at Termination and Victim Line (TA = 25OC) (See Test Circuit)
Channel 1 (500mV/division) Termination Signal, Channel 2 (50mV/division) Victim Voltage. The victim voltage crosstalk
measures 35mV in the critical areas around the system clock. The system clock occurs approximately 4ns before
each data transition. The horizontal dashed lines are 35mV apart. The time scale is 5.0ns/division. (The signal voltage
rise and fall times have been adjusted at the driver to conform to Intel specifications.) Measurements made using
Tektronix TDS820 6 GHz Digitizing Oscilloscope with P6207 FET Probes.
Channel 1
Channel 2
:35mV
Test Circuit Block Diagram
©2000 California Micro Devices Corp. All rights reserved.
2
215 Topaz Street, Milpitas, California 95035
Tel: (408) 263-3214
Fax: (408) 263-7846
www.calmicro.com 7/17/2000