English
Language : 

SF51_9 Datasheet, PDF (2/4 Pages) Bruckewell Technology LTD – PRV 50 - 1000 Volts
SF51_9
PRV : 50 - 1000 Volts
Io : 5.0 Amperes
Rating at 25 °C ambient temperature unless otherwise specifie.
Single phase, half wave, 60 Hz, resistive or inductive load
For capacitive load, derate current by 20%
Rating
Symbol SF51 SF52 SF53 SF54 SF55 SF56 SF57 SF58 SF59 Unit
Maximum Peak Forward
Surge Current 8.3ms
Single half sine wave
IFSM
Superimposed on rated
135
A
load (JEDEC Method
Maximum Peak Forward
VR
0.95
Voltage at IF = 5.0 A
1.7
4.0
V
Maximum DC Reverse
IR
Current Tj = 25 °C
10
mA
at Rated DC Blocking
IR(H)
Voltage Tj = 100 °C
500
mA
Maximum Reverse
Trr
Recovery Time ( Note 1 )
35
Ns
Typical Junction
CJ
Capacitance ( Note 2 )
50
pF
Junction Temperature
TJ
Range
- 65 to + 150
°C
Storage Temperature
TSTG
- 65 to + 150
°C
Range
Notes
(1) Reverse Recovery Test Conditions : IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A.
(2) Measured at 1.0 MHz and applied reverse voltage of 4.0 VDC
Publication Order Number: [SF51_9]
© Bruckewell Technology Corporation Rev. A -2014