ISO806 Datasheet, PDF (4/12 Pages) Burr-Brown (TI) – Isolated 12-Bit Sampling ANALOG-TO-DIGITAL CONVERTER | |||
|
◁ |
PIN #
NAME
DIGITAL
I/O
DESCRIPTION
1
RC
I
2
BUSY
O
3
+5VDIG2
10
+5VDIG1
11
+5VANA
12
R1IN
13
NC
14
R2IN
15
CAP
16
REF
17
AGND
18 SB/BTC
I
19
DGND1
26
DGND2
27 DATACLK
O
28
SDATA
O
Read/Convert. With BUSY high, a falling edge on R/C initiates a new conversion.
At the start of conversion BUSY goes LOW and stays LOW until conversion is complete.
Isolated Digital Supply Volts.
Digital Supply Volts.
Analog Supply Volts.
Analog Input.
No Connection. Leave unconnected.
Analog Input.
Reference Buffer Output. 2.2µF tantalum capacitor to ground.
Reference Input/Output. 2.2µF tantalum capacitor to ground.
Analog Ground.
Selects Straight Binary or Binary Twoâs Complement for Output Data Format.
Digital Ground.
Isolated Ground.
Data Clock Output.
Serial Output Synchronized to DATACLK.
TABLE I. Pin Assignments.
PIN CONFIGURATION
R/C 1
BUSY 2
+5VDIG2 3
28 SDATA
27 DATACLK
26 DGND2
ANALOG
INPUT
RANGE
±10V
0V to 5V
0V to 4V
CONNECT R1IN
VIA 200â¦
TO
VIN
AGND
VIN
CONNECT R2IN
VIA 100â¦
TO
CAP
VIN
VIN
IMPEDANCE
45.7kâ¦
20.0kâ¦
21.4kâ¦
TABLE II. Input Range Connections. See also Figure 3.
ISO806
+5VDIG1 10
+5VANA 11
R1IN 12
NC 13
R2IN 14
19 DGND1
18 SB/BTC
17 AGND
16 REF
15 CAP
R/C BUSY DATACLK OPERATION
â
1
Output Initiates conversion ânâ. Valid data from conversion ân-1â clocked out on SDATA.
0
â
X
New conversion initiated without acquisition of a new signal. Data will be invalid. R/C must be HIGH when BUSY goes HIGH.
X
0
X
New convert commands ignored. Conversion ânâ in progress.
TABLE III. Control Functions
®
ISO806
4
|
▷ |