ELECTRICAL (FULL TEMPERATURE RANGE SPECIFICATIONS)
At VCC = ±15VDC and TA = TMIN and TMAX, unless otherwise noted.
OPA128JM
OPA128KM
OPA128LM
OPA128SM
PARAMETER
CONDITIONS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
TEMPERATURE RANGE
Specification Range
Ambient Temp.
0
+70 0
+70 0
+70 –55
+125
°C
INPUT
BIAS CURRENT(1)
Input Bias Current
OFFSET CURRENT(1)
Input Offset Current
OFFSET VOLTAGE(1)
Input Offset Voltage
Average Drift
Supply Rejection
VCM = 0VDC
VCM = 0VDC
VCM = 0VDC
±2.5 ±8
±1.3 ±4
±0.7 ±2
±43 ±170
pA
1.1
0.6
0.6
18
pA
±2.2mV
±1mV
±750
±1.5mV µV
±20
±10
±5
±10 µV/°C
74 114
80 114
80 114
80 106
dB
±2 ±200
±2 ±100
±2 ±100
±5 ±100 µV/V
VOLTAGE RANGE(2)
Common-Mode Input Range
±10 ±11
±10 ±11
±10 ±11
±10 ±11
V
Commmon-Mode Rejection
VIN = ±10VDC
74 112
80 112
80 112
74 104
dB
OPEN-LOOP GAIN, DC
Open-Loop Voltage Gain
RL ≥ 2kΩ
90 125
104 125
104 125
90 122
dB
RATED OUTPUT
Voltage Output
RL = 2k
±10
±10
±10
±10
V
Current Output
VO = ±10VDC
±5
±5
±5
±5
mA
Short Circuit Current
VO = 0VDC
10 22
10 22
10 22
10 18
mA
POWER SUPPLY
Current, Quiescent
I = 0mADC
0.9 1.8
0.9 1.8
0.9 1.8
0.9
2
mA
NOTES: (1) Offset voltage, offset current, and bias current are measured with the units fully warmed up. (2) If it is possible for the input voltage to exceed the supply
voltage, a series protection resistor should be added to limit input current to 0.5mA. The input devices can withstand overload currents of 0.3mA indefinitely without
damage.
CONNECTION DIAGRAM
Top View
Substrate and Case
Offset
Trim 1
8
7 +VCC
–In 2
OPA128
6 Output
+In 3
4
–VCC
5 Offset
Trim
ABSOLUTE MAXIMUM RATINGS
Supply ........................................................................................... ±18VDC
Internal Power Dissipation(1) .......................................................... 500mW
Differential Input Voltage .............................................................. ±36VDC
Input Voltage Range ..................................................................... ±18VDC
Storage Temperature Range .......................................... –65°C to +150°C
Operating Temperature Range ....................................... –55°C to +125°C
Lead Temperature (soldering, 10s) ............................................... +300°C
Output Short Circuit Duration(2) ................................................ Continuous
Junction Temperature .................................................................... +175°C
NOTES: (1) Packages must be derated based on θCA = 150°C/W or θJA =
200°C/W. (2) Short circuit may be to power supply common only. Rating
applies to +25°C ambient. Observe dissipation limit and TJ.
ORDERING INFORMATION
PRODUCT
OPA128JM
OPA128KM
OPA128LM
OPA128SM
PACKAGE
TO-99
TO-99
TO-99
TO-99
TEMPERATURE
RANGE
0°C to +70°C
0°C to +70°C
0°C to +70°C
–55°C to +125°C
BIAS CURRENT,
max (fA)
±300
±150
±75
±150
PACKAGE INFORMATION
PRODUCT
OPA128JM
OPA128KM
OPA128LM
OPA128SM
PACKAGE
TO-99
TO-99
TO-99
TO-99
PACKAGE DRAWING
NUMBER(1)
001
001
001
001
NOTE: (1) For detailed drawing and dimension table, please see end of data
sheet, or Appendix C of Burr-Brown IC Data Book.
®
3
OPA128