5. PIN DESCRIPTION
Serial Audio Power
VLS
Serial Data Input 1
SDIN1
Serial Data Input 2
SDIN2
Serial Data Input 3
SDIN3
Serial Clock
SCLK
Left/Right Clock
LRCK
Master Clock
MCLK
Digital Power
VD
Ground
GND
Reset
RST
DIF1 / SCL/ CCLK DIF1/SCL/CCLK
DIF0 / SDA / CDIN DIF0/SDA/CDIN
Mode1 / AD0 / CS
M1/AD0/CS
Control Port Power
VLC
1 28
2 27
3 26
4 25
5 24
6 23
7 22
8 21
9 20
10 19
11 18
12 17
13 16
14 15
MUTEC1 Mute Control 1
AOUTA1 Analog Output A1
AOUTB1 Analog Output B1
MUTEC2 Mute Control 2
AOUTA2 Analog Output A2
AOUTB2 Analog Output B2
VA
Analog Power
GND
Ground
AOUTA3 Analog Output A3
AOUTB3 Analog Output B3
MUTEC3 Mute Control 3
VQ
Quiescent Voltage
FILT+ Positive Voltage Reference
M2
Mode 2
Pin Name
VLS
SDIN1
SDIN2
SDIN3
SCLK
LRCK
MCLK
VD
GND
RST
VLC
FILT+
# Pin Description
1 Serial Audio Interface Power (Input) - Determines the required signal level for the serial audio inter-
face. Refer to the Recommended Operating Conditions for appropriate voltages. Applies to pins 2-7.
2 Serial Audio Data Input (Input) - Input for two’s complement serial audio data. SDIN1 corresponds to
3 AOUT1x, SDIN2 corresponds to AOUT2x and SDIN3 corresponds to AOUT3x.
4
5 Serial Clock (Input) - Serial clock for the serial audio interface.
6 Left / Right Clock (Input) - Determines which channel, Left or Right, is currently active on the serial
audio data line. The frequency of the left/right clock must be at the audio sample rate, Fs.
7 Master Clock (Input) - Clock source for the delta-sigma modulator and digital filters. Table 6 illustrates
several standard audio sample rates and the required master clock frequency.
8 Digital Power (Input) - Positive power supply for the digital section. Refer to the Recommended Operat-
ing Conditions for appropriate voltages.
9 Ground (Input) - Ground reference. Should be connected to analog ground.
21
10 Reset (Input) - The device enters a low power mode and all internal registers are reset to their default
settings when low. The control port cannot be accessed when Reset is low.
14 Control Port Interface Power (Input) - Determines the required signal level for the control port and pro-
vides power for bidirectional control port pins. Refer to the Recommended Operating Conditions for
appropriate voltages. Applies to pins 10-13 and 15.
16 Positive Voltage Reference (Output) - Positive reference voltage for the internal sampling circuits.
Requires the capacitive decoupling to GND as shown in the Typical Connection Diagram.
20