English
Language : 

HB75-48 Datasheet, PDF (5/8 Pages) Broadband TelCom Power, Inc. – 48Vin 2.5, 3.3, 5.0, 12, 15, 24Vout 75W
Technical Specification
BTCPowerTM
HB75-48 Series
48Vin 2.5, 3.3, 5, 12, 15, 24Vout 75W
Basic operation and functions
The HB family uses planar transformer
technology to achieve high output current. The
whole unit switches at the fixed frequency for a
predictable EMI performance. The HB Brick has
many standard controls and protection functions.
according to the specification, will turn the unit on
or off.
The positive logic version turns on when pin 2 is
at logic high, and turns off when pin 2 is at logic
low. The unit is on when pin 2 is left open.
Input Power ( pin1, pin4 )
Input power Vin(+) must be connected to Positive
input voltage pin1; Input power Vin(-) must be
connected to Negative input voltage pin4.
The negative logic version turns on when pin 2 is
at logic low and turns off when pin 2 is at logic
high. The pin 2 can be directed to Vin(-), to
enable automatic turn on to the unit without the
need of an external control signal.
Output Power ( pin9, pin5 )
Output power Vout(+) must be connected to
Positive output voltage pin9; Output power
Vout(-) must be connected to Negative output
voltage pin5.
Remote Sense ( pin 8, pin 6 )
Permits the user to maintain the accurate output
voltage at the remote load terminals regardless of
the line drop.
On/Off ( pin 2 )
Permits the user to maintain unit On/Off, in order
to properly sequence different power supplies
and reduce power consumption during the
standby condition. There are two remote control
options available, positive logic and negative logic
is referenced to Vin(-), and typical connections
are shown in Fig 1.
The Sense(-) (pin6) and Sense(+) (pin8) should
be connected at the load or at the point where the
regulation is needed. ( shown on Fig. 2)
Fig. 1: Typical Circuit for On/Off Function
Pin 2 is the "Enable" pin, connecting a TTL
compatible pin. A TTL control signal to this pin,
Fig 2: Remote Sense Circuit
The remote sense feature of the unit
compensates for voltage drop occurring between
the output pins of the unit and load. The Sense(-)
(pin5) and Sense(+)(pin7) should be connected at
the load or at the point where regulation is
required.
If remote Sense is not required, the Sense(-) pin
must be connected to the Vout(-) pin (pin5), and
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 5 of 8
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS HB75-48 Rev2 16-1-04