English
Language : 

BL-HZD39A-TRB Datasheet, PDF (6/8 Pages) BRIGHT LED ELECTRONICS CORP – White Mono-color type Suitable for all SMT assembly methods.
BRIGHT LED ELECTRONICS CORP.
SINCE 1981
BL-HZD39A-TRB
● Reliability Test
Classification Test Item
Reference Standard
Test Conditions
Result
Operation Life MIL-STD-750:1026 Connect with a power If=20mA
MIL-STD-883:1005 Ta=Under room temperature
0/20
JIS-C-7021 :B-1 Test time=1,000hrs
High
Ta=+65℃±5℃
Temperature MIL-STD-202:103B RH=90%-95%
0/20
Endurance High Humidity JIS-C-7021 :B-11 Test time=240hrs
Storage
Test
High
High Ta=+85℃±5℃
Temperature
MIL-STD-883:1008
JIS-C-7021 :B-10
Test time=1,000hrs
0/20
Storage
Low
Low Ta=-35℃±5℃
Temperature JIS-C-7021 :B-12 Test time=1,000hrs
0/20
Storage
Temperature MIL-STD-202:107D -35℃ ~ +25℃ ~ +85℃ ~ +25℃
Cycling
MIL-STD-750:1051 60min 20min 60min 20min
MIL-STD-883:1010 Test Time=5cycle
0/20
JIS-C-7021 :A-4
Environmental Thermal Shock MIL-STD-202:107D -35℃±5℃ ~+85℃±5℃
Test
MIL-STD-750:1051 20min
20min
0/20
MIL-STD-883:1011 Test Time=10cycle
Solder
Resistance
Preheating:
MIL-STD-202:201A 140℃-160℃,within 2 minutes.
MIL-STD-750:2031 Operation heating:
0/20
JIS-C-7021 :A-1
235℃(Max.), within 10seconds. (Max.)
● Judgment criteria of failure for the reliability
Measuring items
Forward voltage
Reverse current
Luminous intensity
Symbol
VF ( V)
IR(uA)
Iv ( mcd )
Measuring conditions
IF=20mA
VR=5V
IF=20mA
Judgement criteria for failure
Over Ux1.2
Over Ux2
Below SX0.5
Note: 1.U means the upper limit of specified characteristics. S means initial value.
2.Measurment shall be taken between 2 hours and after the test pieces have been returned to
normal ambient conditions after completion of each test.
Ver1.0 Page 6 of 8