● Reliability Test
Classification Test Item
Operation Life
Endurance
Test
High
Temperature
High Humidity
Storage
High
Temperature
Storage
Low
Temperature
Storage
Temperature
Cycling
Thermal Shock
Solder
Resistance
Environmental IR-Reflow
Test
Solderability
Solderability
Reference Standard
MIL-STD-750:1026
MIL-STD-883:1005
JIS-C-7021 :B-1
MIL-STD-202:103B
JIS-C-7021 :B-11
MIL-STD-883:1008
JIS-C-7021 :B-10
JIS-C-7021 :B-12
MIL-STD-202:107D
MIL-STD-750:1051
MIL-STD-883:1010
JIS-C-7021 :A-4
MIL-STD-202:107D
MIL-STD-750:1051
MIL-STD-883:1011
MIL-STD-202:201A
MIL-STD-750:2031
JIS-C-7021 :A-1
-
-
-
Test Conditions
Ta=Under RoomTemperature As Per Data
Sheet Maximum Rating
Test Time=1000HRS(-24HRS,+72HRS)ï¼ 
20mA
Ta=+65℃±5℃
RH=90%-95%
Test time=240hrs±2HRS
Result
0/20
0/20
High Ta=+105℃±5℃
Test time=1,000hrs(-24HRS,+72HRS)
0/20
Low Ta=-55℃±5℃
Test time=1,000hrs(-24HRS,+72HRS)
0/20
+105℃ ~ +25℃ ~ -55℃ ~ +25℃
30min 5min 30min 5min
Test Time=10cycle
0/20
IR-Reflow In-Board, 2
(10min)~-40±5℃(10min)
Test Time=10cycle
T.sol=260±5℃
Dwell Time=10±1secs
Times
85±5 ℃
0/20
0/20
Ramp-up rate(183℃ to Peak)+3℃ 1sec
max
0/20
Temp maintain at125±25℃ 120sec max
0/20
Temp maintain above 183℃ 60~150sec
0/20
Peak temperature range 235℃~240℃
0/20
Time within5℃ of actual Pwck
Temperature10-30sec
0/20
Ramp-down rate+6℃ 1sec max
0/20
T.sol=235±5℃
0/20
Immesion time 2±0.5sec
0/20
Immesion rate 25±2.5mm/sec
0/20
Coverage≧95% of the dipped surface
0/20
● Judgment criteria of failure for the reliability
Measuring items
Forward voltage
Reverse current
Luminous intensity
Symbol
VF ( V)
IR(uA)
Iv ( mcd )
Measuring conditions
IF=20mA
VR=5V
IF=20mA
Judgement criteria for failure
Over Ux1.2
Over Ux2
Below SX0.5
Note: 1.U means the upper limit of specified characteristics. S means initial value.
2.Measurment shall be taken between 2 hours and after the test pieces have been returned to
normal ambient conditions after completion of each test.
Ver.2.0 Page 5 of 7