English
Language : 

DVT30-90 Datasheet, PDF (1/4 Pages) BOWEI Integrated Circuits CO.,LTD. – Miniature Digitally Tuned Filters
BOWEI
Miniature Digitally
Tuned Filters
BOWEI INTEGRATED CIRCUITS CO.,LTD.
DVT30-90~DVT550-865
Digitally tuned Fliter
Frequency range:30~1000MHz
Features
High “Q” varactor tuning circuit
Tuning control: 8 bit parallel (TTL compatible)
Input P-1: +10dBm(fc≥90MHz),
0dBm(fc<90MHz)
DC Power: 3~3.6V/10~15mA
Double tuned 0.1dB Chebyshev response
Tuning Speed ≤50us(fc>30MHz)
Up to 251 tuning step
Typical 2~3 octave band cover the frequency
band 30~1000MHz
SMT Package (non-hermetic)
Operating Temperature Range:-40℃~+85℃
Selection Guide:
DVT30-90 (30~90MHz), DVT30-110 (30~110MHz)
DVT90-200(90~200MHz),
DVT200-400(200~400MHz)
DVT400-700(400~700MHz) ,
DVT550-865(550~865MHz)
Note: Custom frequency bands availalbe
Specification
Electronical
Example:DVT30-90-5 means DVT30-90 series with
5% 3dB bandwidth.
Parameter
3dB Bandwidth(%)
% 3dB Bandwidth flatness1)
Insertion Loss at center frequency2)
IL variance3)
Shape factor (BW30/BW3)
Impedance
3~10%
≤1%
2~6dB
≤2dB
≤7:1
50Ω
Maximum VSWR
Input P-1
DC Power(Vcc):
2.0:1max
+10dBm(TYP, fc≥90MHz)
0dBm(TYP, fc<90MHz)
+3.3V/15mA
Note: 1) difference of % 3dB bandwidth within the frequency band, see Page60-61 for typical curves
2) Insertion loss at center frequency is typical one, the wider passband the lower IL. Following method used to calculate
insertion loss:IL ×BW3dB%=20~25, For example % BW is 5% then IL is 4~5dB
3) See Page 60-61 for the typical curves
Enviromental
Standard
Vibration(5~2000Hz) 10G
Shock(11 mSec)
30G
Humidity
0~90%
Special
20G
50G
95%
Operating Temperature
Storage Temperature
Standard
-40~+60℃
-40~+100℃
Special
-40~+85℃
-55~+125℃
●TEL:+86-311-87091891 87091887 ● FAX:+86-311-87091282 ● http://www.cn-bowei.com ● E-mail:cjian@cn-bowei.com