English
Language : 

2036-07-C2LF Datasheet, PDF (3/3 Pages) Bourns Electronic Solutions – 2036 Series - Miniature 3-Pole Gas Discharge Tube
2036 Series - Miniature 3-Pole Gas Discharge Tube
Switch-Grade Failsafe Device Shorting Curve 2036-XX-XF
10.0
5.0
1.0
0.5
0.1
How To Order
2036 - xx - x - nn - F LF
Model Number
Designator
Voltage (Divided by 10)
07 = 75 V 30 = 300 V
09 = 90 V 35 = 350 V
15 = 150 V 40 = 400 V
20 = 200 V 42 = 420 V
23 = 230 V 47 = 470 V
25 = 250 V 60 = 600 V
Leads
A = None
B = 0.8 mm
C = 1 mm
Lead Shape
(See Product Dimension Drawings)
Fail-Short Option
Blank = Standard Product
F = With Fail-Short Mechanism
Lead Free Option
Blank = Standard Product
LF = Lead Free/RoHS Compliant Product (Not available on models
with Fail-Short Mechanism)
0.1
1
10
100
Seconds
ELTGS = Each Line to Ground Simultaneously
NOTE: When using a GDT failsafe device, it is imperative that all components
associated and connected to the GDT with failsafe be tested in their respective
completely integrated environment (finished product) to assure proper operation.
Packaging Specifications
Model 2036-xx-nn ships standard bulk pack, 100 pcs./tray.
REV 05/06
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.