English
Language : 

2027-07_15 Datasheet, PDF (2/2 Pages) Bourns Electronic Solutions – 2-Pole Gas Discharge Tube
2027 Series - 2-Pole Gas Discharge Tube
Product Dimensions
2027-XX-A
DIA.
2.5 ± 0.25
(.098 ± .010)
6.0 ± 0.3
(.236 ± .012)
2027-XX-B — 0.8 ± .04 mm (0.032 ± 0.002 in.) dia. lead wire
2027-XX-C — 1.0 ± .04 mm (0.039 ± 0.002 in.) dia. lead wire
66.0 ± 0.3
(2.60 ± 0.012)
MIN.
8.0
(.314
±
±
0.4
.016)
DIA.
2027-XX-B19 — 0.8 ± 0.04 mm (0.032 ± 0.002 in.) dia. lead wire
(Not available in reelpack)
16.8 ± 0.4
(.661 ± .016)
30.5 ± 0.4
(1.20 ± .016)
LONG
2 PLCS.
2027-XX-B10 — 0.8 ± .04 mm (0.032 ± 0.002 in.) dia. lead wire
2027-XX-C10 — 1.0 ± .04 mm (0.039 ± 0.002 in.) dia. lead wire
(Not available in reelpack)
12.7 ± 0.3
(.500 ± .012)
6.4 ± 0.4
(.252 ± .016)
14.0 ± 0.4
(.551 ± .016)
12.7 ± 0.5
(.500 ± .020)
How to Order
2027 - xx - x nn T1 LF
Model Number Designator
Voltage (Divided by 10)
07 = 75 V
30 = 300 V
09 = 90 V
35 = 350 V
15 = 150 V
40 = 400 V
20 = 200 V
42 = 420 V
23 = 230 V
47 = 470 V
25 = 250 V
60 = 600 V
Leads
A = None
B = 0.8 mm
C = 1 mm
Lead Shape
(See Product Dimension Drawings)
Packaging
Blank = Bulk Packaging (Standard)
T1 = Reelpack (Optional - not available for Models 2027-xx-B19
and 2027-xx-B10/C10)
RoHS Compliant Option
Blank = Standard Product
LF = RoHS Compliant Product
DIMENSIONS:
MM
(INCHES)
1.5 ± 0.3
(.059 ± .012)
2.0 ± 0.3
(.079 ± .012)
8.1 ± 0.3
(.319 ± .012)
Packaging Specifications
Model
2027-XX-A
2027-XX-B
2027-XX-C
2027-XX-B10
2027-XX-C10
2027-XX-B19
2027-XX-C19
2027-XX-BT1
2027-XX-CT1
Standard Packaging Quantity
Bulk (Bag) Tray
Box
Reel
250
1000
100
500
100
500
100
900
100
900
100
500
100
500
1000
1000
2027-XX-BT1 — 0.8 ± 0.04 mm (0.032 ± 0.002 in.) dia. lead wire
Reel is 14 “ in diameter and 2.75 “ wide.
52.4 ± 0.5
(2.1 ± .020)
10.0 ± 0.5
(0.4 ± .020)
REV. 08/15
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.