English
Language : 

TISPPBL3 Datasheet, PDF (1/14 Pages) Bourns Electronic Solutions – DUAL FORWARD-CONDUCTING P-GATE THYRISTORS FOR ERICSSON MICROELECTRONICS SUBSCRIBER LINE INTERFACE CIRCUITS (SLIC)
TISPPBL3
DUAL FORWARD-CONDUCTING P-GATE THYRISTORS
FOR ERICSSON MICROELECTRONICS
SUBSCRIBER LINE INTERFACE CIRCUITS (SLIC)
TISPPBL3 Programmable Protector
Overvoltage Protection for listed SLICs
SLIC †§
TISPPBL3
PBL 3762A/2
✓
PBL 3762A/4
✓
PBL 3764A/4
✓
PBL 3764A/6
✓
PBL 3766
✓
PBL 3766/6
✓
PBL 3767
✓
PBL 3767/6
✓
PBL 3860A/1
✓
PBL 3860A/6
✓
PBL 386 10/2
✓
PBL 386 11/2
✓
PBL 386 14/2
✓
PBL 386 15/2
✓
PBL 386 20/2
✓
PBL 386 21/2
✓
PBL 386 30/2
✓
PBL 386 40/2
✓
PBL 386 50/2
✓
PBL 386 61/2
✓
PBL 386 65/2
✓
PBL 387 10/1
✓
§ See Applications Information for earlier SLIC types.
Rated for International Surge Wave Shapes
Wave Shape
2/10 µs
10/700 µs
10/1000 µs
Standard
ITSP
A
GR-1089-CORE
100
ITU-T K.20, K.21, K.45 40
GR-1089-CORE
30
D Package (Top View)
(Tip) K1
1
8 K1 (Tip)
(Gate) G
2
9 A (Ground)
NC
3
6 A (Ground)
(Ring) K2
4
5 K2 (Ring)
MD6XANA
NC - No internal connection
Terminal typical application names shown in
parenthesis
Device Symbol
K1
K1
A
G1,G2
A
K2
K2
Terminals K1, K2 and A correspond to the alternative
line designators of T, R and G or A, B and C. The
negative protection voltage is controlled by the
voltage, VGG, applied to the G terminal.
SD6XAEA
High Voltage Capability Supports Battery Voltages
Down to -150 V
Specified 2/10 Impulse Limiting Voltage
- Voltage-Time Envelope Guaranteed
- Full -40 °C to 85 °C Temperature Range
Feed-Through Package Connections
- Minimizes Inductive Wiring Voltages
............................................ UL Recognized Components
How To Order
Device
Package
Carrier
For Standard
For Lead Free
Termination Finish Termination Finish
Order As
Order As
TISPPBL3 D (8-pin Small-Outline)
Embossed Tape Reeled
Tube
TISPPBL3DR
TISPPBL3D
TISPPBL3DR-S
TISPPBL3D-S
† Customers are advised to obtain the latest version of the relevant Ericsson Microelectronics SLIC information to verify, before placing orders,
that the information being relied on is current.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Ericsson is a trademark of Telefonaktiebolaget LM Ericsson.
OCTOBER 2000 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.