TISP4XXXJ3BJ Datasheet, PDF (1/8 Pages) Bourns Electronic Solutions – BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
*RoHS VCEOARMVSAPIOILLINAASBNLTE
TISP4290J3BJ THRU TISP4395J3BJ
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP4xxxJ3BJ Overvoltage Protector Series
Ion-Implanted Breakdown Region
-Precise and Stable Voltage
-Low Voltage Overshoot Under Surge
Designed for Transformer Center Tap (Ground Return)
Overvoltage Protection
-Enables GR-1089-CORE Compliance
-High Holding Current Allows Protection of Data Lines
with d.c. Power Feed
Can be Used to Protect Rugged Modems Designed for Exposed
Applications Exceeding TIA-968-A
Device Name
TISP4290J3BJ
TISP4350J3BJ
TISP4395J3BJ
VDRM
V
220
275
320
V(BO)
V
290
350
395
Rated for International Surge Wave Shapes
Wave Shape
Standard
2/10
8/20
10/160
10/700
10/560
10/1000
GR-1089-CORE
IEC 61000-4-5
TIA-968-A (FCC Part 68)
ITU-T K.20/21/45
TIA-968-A (FCC Part 68)
GR-1089-CORE
IPPSM
A
1000
800
400
350
250
200
SMB Package (Top View)
R
Device Symbol
T
T
MDXXBGI
R
SD4XAp
............................................ UL Recognized Components
Description
The range of TISP4xxxJ3BJ devices are designed to limit overvoltages on telecom lines. The TISP4xxxJ3BJ is primarily designed to address
GR-1089-CORE compliance on data transmission lines with d.c. power feeding. When overvoltage protection is applied to transformer
coupled lines from the transformer center tap to ground, the total ground return current can be 200 A, 10/1000 and 1000 A, 2/10. The high
150 mA holding current is set above common d.c. feed system levels to allow the TISP4xxxJ3BJ to reset following a disturbance.
These devices allow signal voltages, without clipping, up to the maximum off-state voltage value, VDRM, see Figure 1. Voltages above VDRM
are limited and will not exceed the breakover voltage, V(BO), level. If sufficient current flows due to the overvoltage, the device switches into a
low voltage on-state condition, which diverts the current from the overvoltage through the device. When the diverted current falls below the
holding current, IH, level the devices switches off and restores normal system operation.
How to Order
Device
Package
Carrier
For Standard
Termination Finish
Order As
TISP4xxxJ3BJ SMB (DO-214AA) Embossed Tape Reeled TISP4xxxJ3BJR
Insert xxx value corresponding to device name.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
JULY 2003 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
For Lead Free
Termination Finish
Order As
TISP4xxxJ3BJR-S
Marking Code Std. Qty.
4xxxJ3
3000