English
Language : 

TISP4070M3BJ_07 Datasheet, PDF (1/12 Pages) Bourns Electronic Solutions – BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
*RoHS COMPLIANT
TISP4070M3BJ THRU TISP4115M3BJ,
TISP4125M3BJ THRU TISP4220M3BJ,
TISP4240M3BJ THRU TISP4400M3BJ
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP4xxxM3BJ Overvoltage Protector Series
ITU-T K.20/21/44/45 rating ................ 4 kV 10/700, 100 A 5/310
Ion-Implanted Breakdown Region
Precise and Stable Voltage
Low Voltage Overshoot under Surge
Device
‘4070
‘4080
‘4095
‘4115
‘4125
‘4145
‘4165
‘4180
‘4200
‘4220
‘4240
‘4250
‘4265
‘4290
‘4300
‘4350
‘4360
‘4395
‘4400
VDRM
V
58
65
75
90
100
120
135
145
155
160
180
190
200
220
230
275
290
320
300
V(BO)
V
70
80
95
115
125
145
165
180
200
220
240
250
265
290
300
350
360
395
400
Low Differential Capacitance ................................. 39 pF max.
®
............................................ UL Recognized Component
SMBJ Package (Top View)
R(B) 1
Device Symbol
T
2 T(A)
MDXXBGE
SD4XAA
R
Terminals T and R correspond to the
alternative line designators of A and B
ITSP
Wave Shape
Standard
A
2/10 µs
GR-1089-CORE 300
8/20 µs
IEC 61000-4-5 220
10/160 µs
FCC Part 68
120
10/700 µs
ITU-T K.20/21/45 100
10/560 µs
FCC Part 68
75
10/1000 µs
GR-1089-CORE
50
Description
These devices are designed to limit overvoltages on the telephone line. Overvoltages are normally caused by a.c. power system or lightning
flash disturbances which are induced or conducted on to the telephone line. A single device provides 2-point protection and is typically used
for the protection of 2-wire telecommunication equipment (e.g. between the Ring and Tip wires for telephones and modems). Combinations of
devices can be used for multi-point protection (e.g. 3-point protection between Ring, Tip and Ground).
The protector consists of a symmetrical voltage-triggered bidirectional thyristor. Overvoltages are initially clipped by breakdown clamping until
the voltage rises to the breakover level, which causes the device to crowbar into a low-voltage on state. This low-voltage on state causes the
current resulting from the overvoltage to be safely diverted through the device. The high crowbar holding current helps prevent d.c. latchup as
the diverted current subsides.
How To Order
Device
Package
Carrier
Order As
TISP 4xxxM3BJ BJ (J-Bend DO-214AA/SMB) Embossed Tape Reeled TISP4xxxM3BJR-S
Insert xxx value corresponding to protection voltages of 070, 080, 095, 115, etc.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
NOVEMBER 1997 - REVISED MAY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.