English
Language : 

TISP1XXXF3 Datasheet, PDF (1/13 Pages) Bourns Electronic Solutions – Overvoltage Protector
*RoHS VCEOARMVSAPIOILLINAASBNLTE
TISP1072F3,TISP1082F3
DUAL FORWARD-CONDUCTING UNIDIRECTIONAL
THYRISTOR OVERVOLTAGE PROTECTORS
TISP1xxxF3 Overvoltage Protector Series
Ion-Implanted Breakdown Region
Precise and Stable Voltage
Low Voltage Overshoot under Surge
DEVICE
VDRM V(BO)
V
V
‘1072F3
- 58 - 72
‘1082F3
- 66 - 82
Planar Passivated Junctions
Low Off-State Current <10 A
Rated for International Surge Wave Shapes
Waveshape
Standard
ITSP
A
2/10 µs
GR-1089-CORE 80
8/20 µs
IEC 61000-4-5
70
10/160 µs
FCC Part 68
60
10/700 µs
ITU-T K.20/21
50
FCC Part 68
10/560 µs
FCC Part 68
45
10/1000 µs GR-1089-CORE 35
D Package (Top View)
T1
NC 2
NC 3
R4
8G
7G
6G
5G
NC - No internal connection
SL Package (Top View)
T
1
G
2
R
3
MD1XAB
Device Symbol
T
R
.......................................UL Recognized Component
Description
These dual forward-conducting unidirectional over-voltage
protectors are designed for the overvoltage protection of
ICs used for the SLIC (Subscriber Line Interface Circuit)
function. The IC line driver section is typically powered with
0 V and a negative supply. The TISP1xxxF3 limits voltages
that exceed these supply rails and is offered in two voltage
variants to match typical negative supply voltage values.
SD1XAA
G
Terminals T, R and G correspond to the
alternative line designators of A, B and C
High voltages can occur on the line as a result of exposure
to lightning strikes and a.c. power surges. Negative tran-
sients are initially limited by breakdown clamping until the
voltage rises to the breakover level, which causes the
device to crowbar. The high crowbar holding current pre-
vents d.c. latchup as the current subsides. Positive tran-
sients are limited by diode forward conduction. These pro-
tectors are guaranteed to suppress and withstand the listed
international lightning surges on any terminal pair.
How To Order
Device
Package
Carrier
For Standard
For Lead Free
Termination Finish Termination Finish
Order As
Order As
D, Small-outline Tape And Reeled TISP1xxxF3DR TISP1xxxF3DR-S
TISP1xxxF3 SL, Single-in-line
Tube
TISP1xxxF3SL TISP1xxxF3SL-S
Insert xxx value corresponding to protection voltages of 072 and 082
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
SEPTEMBER 1993 - REVISED FEBRUARY 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.