English
Language : 

TIC226 Datasheet, PDF (1/4 Pages) Power Innovations Ltd – SILICON TRIACS
TIC226 SERIES
SILICON TRIACS
8 A RMS
Glass Passivated Wafer
400 V to 800 V Off-State Voltage
Max IGT of 50 mA (Quadrants 1 - 3)
This series is currently available,
but not recommended for new
designs.
MT1
MT2
G
TO-220 PACKAGE
(TOP VIEW)
1
2
3
Pin 2 is in electrical contact with the mounting base.
MDC2ACA
absolute maximum ratings over operating case temperature (unless otherwise noted)
RATING
TIC226D
Repetitive peak off-state voltage (see Note 1)
TIC226M
TIC226S
TIC226N
Full-cycle RMS on-state current at (or below) 85°C case temperature (see Note 2)
Peak on-state surge current full-sine-wave at (or below) 25°C case temperature (see Note 3)
Peak gate current
Peak gate power dissipation at (or below) 85°C case temperature (pulse width ≤ 200 μs)
Average gate power dissipation at (or below) 85°C case temperature (see Note 4)
Operating case temperature range
Storage temperature range
Lead temperature 1.6 mm from case for 10 seconds
SYMBOL
VDRM
IT(RMS)
ITSM
IGM
PGM
PG(AV)
TC
Tstg
TL
VALUE
400
600
700
800
8
70
±1
2.2
0.9
-40 to +110
-40 to +125
230
UNIT
V
A
A
A
W
W
°C
°C
°C
NOTES: 1. These values apply bidirectionally for any value of resistance between the gate and Main Terminal 1.
2. This value applies for 50-Hz full-sine-wave operation with resistive load. Above 85°C derate linearly to 110°C case temperature at
the rate of 320 mA/°C.
3. This value applies for one 50-Hz full-sine-wave when the device is operating at (or below) the rated value of on-state current. Surge
may be repeated after the device has returned to original thermal equilibrium. During the surge, gate control may be lost.
4. This value applies for a maximum averaging time of 20 ms.
electrical characteristics at 25°C case temperature (unless otherwise noted )
IDRM
PARAMETER
Repetitive peak
off-state current
IGT
Gate trigger
current
VGT
Gate trigger
voltage
VT
On-state voltage
VD = rated VDRM
Vsupply = +12 V†
Vsupply = +12 V†
Vsupply = -12 V†
Vsupply = -12 V†
Vsupply = +12 V†
Vsupply = +12 V†
Vsupply = -12 V†
Vsupply = -12 V†
IT = ±12 A
† All voltages are with respect to Main Terminal 1.
TEST CONDITIONS
IG = 0
RL = 10 Ω
RL = 10 Ω
RL = 10 Ω
RL = 10 Ω
RL = 10 Ω
RL = 10 Ω
RL = 10 Ω
RL = 10 Ω
IG = 50 mA
TC = 110°C
tp(g) > 20 μs
tp(g) > 20 μs
tp(g) > 20 μs
tp(g) > 20 μs
tp(g) > 20 μs
tp(g) > 20 μs
tp(g) > 20 μs
tp(g) > 20 μs
(see Note 5)
MIN TYP MAX UNIT
±2
mA
6
50
-12 -50
-10 -50
mA
25
0.7
2
-0.8
-2
-0.8
-2
V
0.9
2
±1.5 ±2.1
V
APRIL 1971 - REVISED SEPTEMBER 2002
Specifications are subject to change without notice.
1