English
Language : 

TBU-DT065-500-WH_12 Datasheet, PDF (1/5 Pages) Bourns Electronic Solutions – TBU-DT Series - TBU High-Speed Protectors
*RoHS COMPLIANT
00T78455
Features
■ Superior circuit protection
■ Overcurrent and overvoltage protection
■ Blocks surges up to rated limits
■ High-speed performance
■ Small SMT package
■ RoHS compliant*
■ Agency listing:
Applications
■ Ethernet ports
■ Protection modules and dongles
■ Process control equipment
■ Test and measurement equipment
■ General electronics
TBU-DT Series - TBU® High-Speed Protectors
General Information
The TBU-DT Series of Bourns® TBU® (Transient Blocking Unit) products are very low
capacitance dual unidirectional high-speed surge protection components designed to
protect against faults caused by short circuits, AC power cross, induction and lightning
surges.
The TBU-DT series is a unidirectional TBU® device; the TBU® protector will trip in less
than 1 μs when the current reaches the maximum value in one direction only, that is when
Pin 1 is positive in voltage with respect to Pin 2, and Pin 4 is positive with respect to Pin 3.
No current limiting exists in the opposite polarity, and the TBU® device appears as resis-
tive in nature. The reverse current should not exceed the maximum trigger current level of
the TBU® device. An external diode may be used to prevent reverse current in DC biased
applications.
The TBU® protector blocks surges and provides an effective barrier behind which sensitive
electronics will not be exposed to large voltages or currents during surge events. After the
surge, the TBU® device resets when the voltage across the TBU® device falls to the Vreset
level. The TBU® device will automatically reset on lines which have no DC bias or have
DC bias below Vreset (such as unpowered signal lines).
The TBU® device is provided in a surface mount DFN package and meets industry
standard requirements such as RoHS and Pb Free solder reflow profiles.
Line Side 1
2 Load Side
Line Side
4
Load Side
3
TBU® Device
Agency Listing
Description
UL
File Number: E315805
Absolute Maximum Ratings (@ TA = 25 °C Unless Otherwise Noted)
Symbol Parameter
Part Number
Value
Unit
Vimp
Peak impulse voltage withstand with duration less than 10 ms
TBU-DT065-xxx-WH
TBU-DT085-xxx-WH
650
850
V
Vrms
Continuous A.C. RMS voltage
TBU-DT065-xxx-WH
300
TBU-DT085-xxx-WH
425
V
Top
Operating temperature range
-40 to +125
°C
Tstg
Storage temperature range
-65 to +150
°C
Electrical Characteristics (@ TA = 25 °C Unless Otherwise Noted)
Symbol
Itrigger
Parameter
Current required for the device to go from operating state to
protected state
Part Number
TBU-DTxxx-100-WH
TBU-DTxxx-200-WH
TBU-DTxxx-300-WH
TBU-DTxxx-500-WH
Rdevice
Series resistance of
the TBU® device
Vimp = 650 V Itrigger (min.) = 100 mA
Vimp = 650 V Itrigger (min.) = 200 mA
Vimp = 650 V Itrigger (min.) = 300 mA
Vimp = 650 V Itrigger (min.) = 500 mA
TBU-DT065-100-WH
TBU-DT065-200-WH
TBU-DT065-300-WH
TBU-DT065-500-WH
Vimp = 850 V Itrigger (min.) = 100 mA
Vimp = 850 V Itrigger (min.) = 200 mA
Vimp = 850 V Itrigger (min.) = 300 mA
Vimp = 850 V Itrigger (min.) = 500 mA
TBU-DT085-100-WH
TBU-DT085-200-WH
TBU-DT085-300-WH
TBU-DT085-500-WH
Rmatch
tblock
IQ
Vreset
Rth(j-l)
Rth(j-l)
Package resistance matching of the TBU® device #1 - TBU® device #2
Time for the device to go from normal operating state to protected state
Current through the triggered TBU® device with 50 Vdc circuit voltage
Voltage below which the triggered TBU® device will transition to normal operating state
Junction to package pads - FR4 using recommended pad layout
Junction to package pads - FR4 using heat sink on board (6 cm2)
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Min.
100
200
300
500
-0.5
0.25
10
Typ.
150
300
450
750
8.5
5.6
4.6
4.0
10.3
7.4
6.5
5.8
0.50
14
116
96
Max.
200
400
600
1000
10.0
6.6
5.6
4.8
12.1
8.7
7.7
6.9
+0.5
1
1.00
18
Unit
mA
Ω
Ω
µs
mA
V
°C/W
°C/W