Features
■ Extremely high speed performance
■ Blocks high voltages and currents
■ Two TBU® protectors in one small package
■ Simple, superior circuit protection
■ Minimal PCB area
■ RoHS compliant*, UL Recognized
Bourns® Model P500-G and P850-G Series
TBU® HSPs are not recommended for POTS
applications. This series is suited for
applications requiring a dual bidirectional device
where 50 ohms of series resistance is acceptable.
For new SLIC applications, we recommend that
customers evaluate our TBU-PL Series.
P500-G and P850-G Series Dual TBU® High-Speed Protectors
Transient Blocking Units - TBU® Devices
Bourns® Model P500-G and P850-G TBU® products are dual
high-speed bidirectional protection components, constructed
using MOSFET semiconductor technology, designed to protect
against faults caused by short circuits, AC power cross,
induction and lightning surges.
The TBU® high speed protector, triggering as a function of
the MOSFET, blocks surges and provides an effective barrier
behind which sensitive electronics are not exposed to large
voltages or currents during surge events. The TBU® device is
provided in a surface mount DFN package and meets industry
standard requirements such as RoHS and Pb Free solder
reflow profiles.
Agency Approval
UL recognized component File # E315805.
Industry Standards
Telcordia
ITU-T
Description
GR-1089
Port Type 2, 4
Port Type 3, 5
K.20, K.20E, K.21, K.21E, K.45
Model
P500-G
P850-G
P850-G
Absolute Maximum Ratings (Tamb = 25 °C)
Symbol Parameter
Value
Unit
Vimp
Maximum protection voltage for impulse faults with rise time ≥ 1 µsec
P500-Gxxx-WH
P850-Gxxx-WH
500
850
V
Vrms
Maximum protection voltage for continuous Vrms faults
P500-Gxxx-WH
300
P850-Gxxx-WH
425
V
Top
Operating temperature range
Tstg
Storage temperature range
-40 to +85
°C
-65 to +150
°C
Electrical Characteristics (Tamb = 25 °C)
Symbol
Iop
Itrigger
Iout
Rdevice
Rbal
tblock
Iquiescent
Vreset
Parameter
Maximum current through the device that will not cause
current blocking
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
Typical current for the device to go from normal operating
state to protected state
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
Maximum current through the device
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
Series resistance of the TBU® device
Line-to line series resistance difference between two TBU® devices
Maximum time for the device to go from normal operating
state to protected state
Current through the triggered TBU® device with 50 Vdc circuit
voltage
Voltage below which the triggered TBU® device will transition to
normal operating state
Min.
Typ.
150
275
150
275
50
0.7
22
The P-G series TBU® devices are bidirectional; specifications are valid in both directions.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Max.
100
200
100
200
200
400
200
400
55
2
1
Unit
mA
mA
mA
Ω
Ω
µs
mA
V