P500-G_10 Datasheet, PDF (1/7 Pages) Bourns Electronic Solutions – TBU® P500-G and P850-G Protectors | |||
|
*RoHS COMPLIANT
Features
â Formerly
brand
â Extremely high speed performance
â Blocks high voltages and currents
â Two TBU® protectors in one small package
â Simple, superior circuit protection
â Minimal PCB area
â RoHS compliant*, UL Recognized
The P500-G & P850-G Series are
currently available, but not recom-
mended for new designs. Bourns®
TBU-PL Series is preferred.
TBU® P500-G and P850-G Protectors
Transient Blocking Units - TBU® Devices
Bourns® Model P500-G and P850-G TBU® products are high
speed bidirectional protection components, constructed
using MOSFET semiconductor technology, designed to protect
against faults caused by short circuits, AC power cross,
induction and lightning surges.
The TBU® high speed protector, triggering as a function of
the MOSFET, blocks surges and provides an effective barrier
behind which sensitive electronics are not exposed to large
voltages or currents during surge events. The TBU® device is
provided in a surface mount DFN package and meets industry
standard requirements such as RoHS and Pb Free solder
reï¬ow proï¬les.
Agency Approval
UL recognized component File # E315805.
Industry Standards
Telcordia
ITU-T
Description
GR-1089
Port Type 2, 4
Port Type 3, 5
K.20, K.20E, K.21, K.21E, K.45
Model
P500-G
P850-G
P850-G
Absolute Maximum Ratings (Tamb = 25 °C)
Symbol Parameter
Value
Unit
Vimp
Maximum protection voltage for impulse faults with rise time ⥠1 µsec
P500-Gxxx-WH
P850-Gxxx-WH
500
850
V
Vrms
Maximum protection voltage for continuous Vrms faults
P500-Gxxx-WH
300
P850-Gxxx-WH
425
V
Top
Operating temperature range
Tstg
Storage temperature range
-40 to +85
°C
-65 to +150
°C
Electrical Characteristics (Tamb = 25 °C)
Symbol Parameter
P500-G120-WH
Iop
Maximum current through the device that will not cause
current blocking
P500-G200-WH
P850-G120-WH
P850-G200-WH
Itrigger
Typical current for the device to go from normal operating
state to protected state
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
Iout
Maximum current through the device
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
Rdevice
Rbal
tblock
Series resistance of the TBU® device
Line-to line series resistance difference between two TBU® devices
Maximum time for the device to go from normal operating
state to protected state
Iquiescent
Current through the triggered TBU® device with 50 Vdc circuit
voltage
Vreset
Voltage below which the triggered TBU® device will transition to
normal operating state
The P-G series TBU® devices are bidirectional; speciï¬cations are valid in both directions.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Speciï¬cations are subject to change without notice.
Customers should verify actual device performance in their speciï¬c applications.
Min.
Typ.
150
275
150
275
50
0.7
22
Max.
100
200
100
200
200
400
200
400
55
2
1
Unit
mA
mA
mA
Ω
Ω
µs
mA
V
|
▷ |