English
Language : 

CG0603MLC-12LE Datasheet, PDF (1/3 Pages) Bourns Electronic Solutions – ChipGuard® MLC Series - ESD Protectors
AEC*ARPoPHRSOCVOEMDP(LSIeAlNecTt Models)
Features
■ Select models are compliant with
AEC-Q200 Rev-C Stress Test Qualification
for Passive Components in Automotive
Applications (see chart below)
■ RoHS compliant*
■ ESD protection >25 kV
■ Low capacitance <0.5 pF
■ Low leakage current <50 nA
Applications
■ HDMI 1.4
■ Digital Visual Interface (DVI)
■ USB 3.0 / USB OTG
■ Memory protection
■ SIM card ports
■ Automotive
ChipGuard® MLC Series - ESD Protectors
General Information
The ChipGuard® MLC Series has been specifically designed to protect sensitive
electronic components from electrostatic discharge damage. The MLC family has been
designed to protect equipment to IEC61000-4-2, Level 4 (±8 kV Contact / ±15 kV Air
Discharge) ESD specifications targeted for high speed USB 3.0/USB OTG, HDMI 1.4,
DVI or IEEE1394 applications.
The ChipGuard® MLC Series has been manufactured to provide low 0.5 pF capacitance
and leakage currents less than 50 nA with excellent clamp qualities, making the family
almost transparent under normal working conditions.
AEC Approved Models
Model
CG0603MLC-05E
CG0603MLC-12E
AEC-Q200
✓ Yes
✓ Yes
Device Symbol
V
Electrical Characteristics @ 25 °C (unless otherwise noted)
Parameter
Symbol
Typical Continuous Operating Voltage
Typical Clamping Voltage (Note 1)
Maximum Capacitance @ 1 VRMS 1 MHz
Maximum Leakage Current @ Max. VDC
Typical Trigger Voltage (Note 2)
Maximum Response Time
ESD Protection:
Per IEC 61000-4-2 Level 4
Min. Contact Discharge
Min. Air Discharge
Min. Air Discharge
Operating Temperature
Storage Temperature
VDC
VC
CO
IL
VT
RT
TOPR
TSTG
3.3LG
3.3
05LG 12LG
5
12
-40 to +85
CG0402MLC-
Unit
24LG 3.3LGA 05LGA 12LGA 24LGA
24
3.3
5
12
24
V
25
V
0.5
pF
5
nA
250
V
1
ns
±8
kV
±15 (Note 3)
kV
±25
kV
-40 to +125
˚C
-55 to +150
˚C
Parameter
CG0603MLC-
Symbol
3.3LE 05E 05LE 12E 12LE 24LE 3.3LEA 05LEA 12LEA 24LEA
Typical Continuous Operating Voltage
VDC
3.3
5
5 12 12 24 3.3 5 12 24
Typical Clamping Voltage (Note 1)
VC
25 20 25 30
25
Maximum Capacitance @ 1 VRMS 1 MHz
CO
0.5
Maximum Leakage Current @ Max. VDC
IL
5 50 5 50
5
Typical Trigger Voltage (Note 2)
VT
250 150 250 150
250
Maximum Response Time
RT
1
ESD Protection:
Per IEC 61000-4-2 Level 4
Min. Contact Discharge
Min. Air Discharge
Min. Air Discharge
±8
±15 (Note 3)
±25
Operating Temperature
Storage Temperature
TOPR
TSTG
-40 to +85
-55 to +150
-40 to +125
Notes:
1. Per IEC 61000-4-2, Level 4 8 kV Contact Discharge. Measurement 30 ns after initiation of pulse.
2. Per IEC 61000-4-2, Level 4 8 kV Contact Discharge. Measurement at maximum pulse voltage.
3. IEC 61000-4-2 ESD Performance for CG0603MLC-05E and CG0603MLC-12E devices will meet minimum 100 reps.
Some shifting in characteristics may occur when tested over several hundred ESD pulses. All other part numbers listed will meet
IEC 61000-4-2 ESD Performance with minimum 1000 reps without degradation in performance.
Unit
V
V
pF
nA
V
ns
kV
kV
kV
˚C
˚C
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.