CDSOT23-T03LC~T36LC – Low Capacitance TVS Diode Array Series
General Information
The markets of portable communications, computing and video equipment are
challenging the semiconductor industry to develop increasingly smaller electronic
components.
Bourns offers Transient Voltage Suppressor Array Diodes for surge and ESD
protection applications, in compact chip package SOT23 size format. The Transient
Voltage Supressor Array series offers a choice of voltage types ranging from 3 V to
36 V. Bourns® Chip Diodes conform to JEDEC standards, are easy to handle on
standard pick and place equipment and their flat configuration minimizes roll away.
The Bourns® device will meet IEC 61000-4-2 (ESD), IEC 61000-4-4 (EFT) and IEC
61000-4-5 (Surge) requirements.
Thermal Characteristics (@ TA = 25 °C Unless Otherwise Noted)
Parameter
Symbol
Value
Unit
Operating Temperature
TJ
-55 to +150
°C
Storage Temperature
TSTG
-55 to +150
°C
2
1
3
Electrical Characteristics (@ TA = 25 °C Unless Otherwise Noted)
Parameter
Symbol
T03LC
T05LC
CDSOT23-
T08LC
T12LC
T15LC
Breakdown Voltage @ 1 mA
Working Peak Voltage
Maximum Clamping Voltage
VC @ IP1
Maximum Clamping Voltage
@ 8/20 µs VC @ IPP1
Maximum Leakage Current
@ VWM
Maximum Cap Bidirectional
@ 0 V, 1 MHz
Peak Pulse Power (tp = 8/20 µs)2
VBR
VWM
VF
VF
ID
C j(SD)
PPP
4.0
3.3
7.0
10.9 V
@ 43 A
125
5
6.0
5.0
9.8
13.5 V
@ 42 A
20
5
8.5
8.0
13.4
16.9 V
@ 34 A
10
5
13.3
12.0
19.0
25.9 V
@ 27 A
2
5
500
16.7
15.0
24.0
30.0 V
@ 17 A
1
5
T24LC
26.7
24.0
43.0
49.0 V
@ 12 A
1
5
Unit
T36LC
40.0
V
36.0
V
51.0
V
76.8 V
@9A
V
1
µA
5
pF
W
Notes:
1. See Pulse Wave Form.
2. See Peak Pulse Power vs. Pulse Time.
3. Positive Potential is applied from Pin 1 to Pin 2 with Pin 2 as ground.
4. Do not test or surge from Pin 2 to Pin 1.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.