English
Language : 

2095-80 Datasheet, PDF (1/2 Pages) Bourns Electronic Solutions – High Voltage 2-Electrode Gas Discharge Tube
*RoHS COMPLIANT
Features
■ Size: 8 mm diameter, 8 mm length
■ Axial leaded device
■ High voltage range up to 6 kV
■ High insulation resistance
■ RoHS compliant*
■
UL Recognized
Applications
■ Industrial equipment/electronics
■ Telecommunications electronics
■ Consumer electronics
2095 Series High Voltage 2-Electrode Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12 and IEC 61643-311.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2095-80
800 V
< 1100 V
< 1200 V
2095-100
1000 V
< 1300 V
< 1400 V
Model No.
2095-140
1400 V
< 2100 V
< 2200 V
2095-160
1600 V
< 2300 V
< 2400 V
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2095-250
2500 V
< 3500 V
< 3600 V
2095-270
2700 V
< 3600 V
< 3800 V
Model No.
2095-300
3000 V
< 4100 V
< 4200 V
2095-350
3500 V
< 4900 V
< 5000 V
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2095-450
4500 V
< 5800 V
< 6000 V
Model No.
2095-500
5000 V
< 6000 V
< 6400 V
2095-600
6000 V
< 7000 V
< 7800 V
Insulation Resistance (IR) 1............................. 250/500/1000 Vdc.............................................> 1 GΩ
Glow Voltage ................................................... 10 mA................................................................~ 60 V
Arc Voltage ...................................................... 1 A.....................................................................~ 15 V
Capacitance..................................................... 1 MHz ...............................................................< 1.5 pF
Impulse Discharge Current
2095-80 through 2095-250 ......................... 8,000 A, 8/20 µs................................................ 1 operation
5,000 A, 8/20 µs................................................ 10 operations
2095-270 through 2095-600 ....................... 5,000 A, 8/20 µs................................................ 1 operation
3,000 A, 8/20 µs................................................ 10 operations
Alternating Discharge Current
2095-80 through 2095-250 ......................... 2 Arms, 50 Hz, 1 second................................... 1 operation min.
10 Arms, 50 Hz, 9 cycles .................................. 1 operation min.
2095-270 through 2095-300 ....................... 3 Arms, 50 Hz, 1 second................................... 1 operation min.
5 Arms, 50 Hz, 9 cycles .................................... 1 operation min.
2095-350 through 2095-600
2.5 Arms, 50 Hz, 1 second................................ 1 operation min.
5 Arms, 50 Hz, 9 cycles .................................... 1 operation min.
Impulse Life ..................................................... 100 A, 10/1000 µs.............................................> 100 operations 2
Operating Temperature............................................................................................................... -30 to +85 °C
Storage Temperature .................................................................................................................. -40 to +115 °C
Climatic Category (IEC 60068-1)................................................................................................ 40 / 90 / 21
Notes:
• UL Recognized component: UL File E135337.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
Note 1:
DC Breakdown
IR Measuring Voltage
800-1000 V..............................250 V
1400-2000 V............................500 V
2500-6000 V............................1000 V
Note 2: Model 2095-270 and 2095-300 meet >300 operations at 100 A, 10/1000 µs.
2095-200
2000 V
< 2700 V
< 2800 V
2095-400
4000 V
< 5300 V
< 5500 V
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.