English
Language : 

2036-07_16 Datasheet, PDF (1/3 Pages) Bourns Electronic Solutions – Miniature 3-Pole Gas Discharge Tube
*RoHS VCEOARMVSAPIOILLINAASBNLTE
Features
n Balanced Mini-TRIGARD™
n 5 mm diameter, 7.5 mm long
n UL Recognized
n RoHS compliant* versions available
Applications
n Telecommunications
n Industrial electronics
n Commercial electronics
n Consumer electronics
n Automotive, aircraft, military electronics
*RoHS COMPLIANT
2036 Series - Miniature 3-Pole Gas Discharge Tube
Characteristics
Test Methods per
Characteristic
ITU-T
K.12,
IEEE
C62.31
and
LEAD
IFERECE
61643-311
GDT
standards.
Model
2036-07
2036-09
2036-15
No.
2036-20
DC Sparkover ±20 % @ 100 V/s
75 V
90 V
150 V
200 V
Impulse Sparkover (1)
100 V/µs
250 V
250 V
350 V
425 V
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
525 V
2036-30
300 V
2350553LVER006EAoR-DHS3VVSFIO5RCNEOSEMAPRLEIANT*
500 V
575 V
Model No.
2036-40
2036-42
400 V
420 V
Impulse Sparkover (1)
100 V/µs
500 V
600 V
650 V
675 V
1000 V/µs
650 V
750 V
825 V
850 V
2036-23
230 V
450 V
600 V
2036-47
470 V
750 V
950 V
2036-25
250V
475 V
625 V
2036-60
600 V
850 V
1100 V
(1) Impulse Sparkover voltage is defined as typical values of distribution.
Impulse Transverse Delay...................1000 V/µs................................................................................ < 75 ns
Insulation Resistance..........................100 V (50 V for Model 2036–07 & 2036-09)............................ > 1010 Ω
Glow Voltage.......................................10 mA...................................................................................... ~ 70 V
Arc Voltage..........................................1 A........................................................................................... ~ 10 V
Glow-Arc Transition Current................................................................................................................ < 0.5 A
Capacitance........................................1 MHz...................................................................................... < 2 pF
DC Holdover Voltage(2) .......................135 V, (52 V for Model 2036-07 & 2036-09,............................ < 150 ms
80 V for Model 2036-15)
Impulse Discharge Current..................20000 A, 8/20 µs (3).................................................................. 1 operation minimum
10000 A, 8/20 µs..................................................................... > 10 operations
2000 A, 10/350 µs................................................................... 1 operation
200 A, 10/1000 µs .................................................................. > 300 operations
200 A, 10/700 µs .................................................................... > 500 operations
Alternating Discharge Current.............20 Arms, 1 s (3)......................................................................... 1 operation minimum
10 Arms, 1 s............................................................................ > 10 operations
Storage Temperature........................................................................................................................... -55 to +105 °C
Operating Temperature........................................................................................................................ -55 to +105 °C
Climatic Category (IEC 60068-1)........................................................................................................ 55/105/21
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering
process that does not exceed 210 °C.
Notes:
• UL recognized component, UL File E153537.
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).
• The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
(2) Network applied.
(3) DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.