English
Language : 

2030-23T Datasheet, PDF (1/3 Pages) Bourns Electronic Solutions – Fast Acting 3-Electrode Miniature Gas Discharge Tube
*RoHS VCEOARMVSAPIOILLINAASBNLTE
Features
■ Size: 5 mm diameter, 7.3 mm length
■ Very fast acting
■ Small size
■ Stable breakdown throughout life
■ Designed to operate with TBU® devices
■ RoHS compliant* versions available
■
UL Recognized
Applications
■ Telecommunications
■ Industrial electronics
■ Avionics
2030-xxT-SM Series - Fast Acting 3-Electrode Miniature Gas Discharge Tube
Characteristics
Characteristic
Minimum DC Sparkover (100 V/s) Throughout Service Life
Maximum Impulse Sparkover (5k V 1.2/50 µs) Throughout Service Life
2030-23T
185 V
650 V
Model No.
2030-42T
360 V
850 V
Insulation Resistance (IR) ..................50 V / 100 V............................................................................ > 1010 Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................>1 A ........................................................................................ ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage (Network Applied per ITU-T K.12)
2030-23T .......................................80 V ....................................................................................... < 150 ms
2030-42T .......................................135 V ..................................................................................... < 150 ms
Impulse Service Life ...........................8/20 µs, 4 kA........................................................................... 1 operation1
1.2 µs - 500 V, 8/20 µs - 250 A ............................................... 150 operations1,2
10/1000 µs, 1 kV, 100 A.......................................................... 25 operations1
2/10 µs, 6 kV, 500 A................................................................ 10 operations1
10/700 µs, 6 kV, 150 A............................................................ 5 operations1
AC Service Life...................................600 V, 1 Arms, 0.2 sec............................................................ 5 operations
Operating and Storage Temperature .................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) ....................................................................................................... 40 / 90 / 21
Notes:
1 The rated discharge current is the total current equally divided between each line to ground and operation(s) are performed in both
polarities. The polarity of lightning surge tests should be reversed between consecutive surges.
2 Per IEC 61643-21.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
Applications
Port Protection
CanBus
RS232
RS422
RS485
RS485
SDI
GDT Device P/N
2030-23T-SM-RPLF
2030-23T-SM-RPLF
2030-23T-SM-RPLF
2030-23T-SM-RPLF
2030-42T-SM-RPLF
2030-23T-SM-RPLF
TBU® Device P/N
TBU-CA065-100-WH
TBU-CA065-200-WH
TBU-CA065-200-WH
TBU-CA065-200-WH
TBU-CA085-200-WH
TBU-CA065-100-WH
“TBU” is a registered trademark of Bourns, Inc. in the United States and other countries.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.