2027-35-SMLF Datasheet, PDF (1/2 Pages) Bourns Electronic Solutions – 2027-xx-SM Precision Gas Discharge Tube Surge Protector | |||
|
*RoHS VCEOARMVSAPIOILLINAASBNLTE
Features
â Surface mount for economical assembly
â High surge current rating
â Low capacitance and insertion loss
â Stable breakdown throughout life
â 8 mm diameter, 6 mm long
â UL Recognized
Applications
â Telecommunications
â Industrial electronics
â Commercial electronics
â Automotive, aircraft, military electronics
2027-xx-SM Precision Gas Discharge Tube Surge Protector
Bourns offers an 8 x 6 mm Surface Mount (SM) 2-electrode GDT surge protection device. The industry-leading quality and features
of Bourns® 2027 Series GDT continue in this new SM version. Compatible with âpick and placeâ assembly systems, the 2027-SM is
ideal for compact applications such as PCBs for telecommunications, commercial and industrial applications.
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Characteristic
DC Sparkover ±15 %
(±20 % for Models 2027-07-SM &
2027-09-SM) @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Model No.
2027-07-SM 2027-09-SM 2027-15-SM 2027-20-SM 2027-23-SM 2027-25-SM
75 V
90 V
150 V
200 V
230 V
250 V
300 V
500 V
300 V
500 V
350 V
575 V
400 V
600 V
450 V
675 V
475 V
700 V
Characteristic
DC Sparkover ±15 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2027-30-SM
300 V
2027-35-SM
350 V
Model No.
2027-40-SM 2027-42-SM
400 V
420 V
2027-47-SM
470 V
2027-60-SM
600 V
550 V
800 V
600 V
875 V
650 V
925 V
675 V
950 V
725 V
1000 V
850 V
1100 V
Insulation Resistance ...................................... 100 V (50 V for Models 2027â07-SM
& 2027-09-SM) .................................................> 1010 Ω
Glow Voltage ................................................... 10 mA................................................................~ 70 V
Arc Voltage ...................................................... > 1A ..................................................................~ 10 V
Glow-Arc Transition Current .......................................................................................................< 0.5 A
Capacitance .................................................... 1 MHz ...............................................................< 1 pF
DC Holdover Voltage** .................................... 135 V, (52 V for Models 2027-07-SM
& 2027-09-SM; 80 V for Model 2027-15-SM)...< 150 ms
Impulse Discharge Current.............................. 25000 A, 8/20 µs*** ........................................... 1 operation minimum
10000 A, 8/20 µs...............................................> 10 operations
2500 A, 10/350 µs ............................................ 2 operations
500 A, 10/1000 µs ............................................> 400 operations
100 A, 10/1000 µs or 10/700 µs .......................> 1000 operations
Alternating Discharge Current ......................... 65 Arms, 11 cycles*** ........................................ 1 operation minimum
10 Arms, 1 s......................................................> 10 operations
Operating Temperature............................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1)................................................................................................ 40/90/21
Notes:
⢠UL recognized component, UL File E153537.
⢠Model number marking on tube: 27-xxxV.
⢠Surface Mount (SM) parts may show a temporary increase in DCBD after the solder reï¬ow process. Most devices will recover
within 24 hours time. It should be noted that there is no quality defect nor change in protection levels during the temporary change
in DCBD.
⢠Sparkover limits ±20 % after life, IR >108 Ω (-25 %, +30 % for Models 2027-07-SM, 2027â09-SM and 2027â60-SM).
⢠At delivery AQL 0.65 Level II, DIN ISO 2859.
** Network applied.
*** DC Sparkover may exceed ±20 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Speciï¬cations are subject to change without notice.
Customers should verify actual device performance in their speciï¬c applications.
|
▷ |