English
Language : 

1530-1 Datasheet, PDF (1/3 Pages) Bourns Electronic Solutions – PoE Ethernet Surge Protector
Features
■ GDT-TBU® High-Speed Protector technology
■ Low impulse voltage let-through
■ Low impulse current let-through
■ High surge current rating
■ 10/100/1000 Mbps data compatibility
■ Transparent to Mode A or Mode B
■ Compatible with Class 4 power levels
■ UL Listed per E153537 Vol 2 Sec 2
Applications
■ Data communications
■ Highly exposed Ethernet
■ Telecommunication and indoor industrial
installations
■ Surveillance cameras
■ Remote power and communication
1530-1 Series PoE Ethernet Surge Protector
The Bourns® Model 1530-1 Series Commercial PoE Ethernet Surge Protectors incorporate state-of-the-art gas discharge tube and surge
limiting technologies to provide the highest protection level offered by Bourns. The Model 1530-1 Series is designed to meet applicable
Telcordia GR-1089 Level 1 and Level 2 Surge and AC Power Fault specifications on the data signal line while allowing operations up to
35 watts (employing both Mode A and B combination) at 57 volts. The Model 1530-1 Series enclosure is flame retardant and manufactured
with a high impact resistant plastic.
Characteristics
Test methods per UL 497B, GR-1089, CSA C22.2, IEC 61000-4-5, and IEEE 802.3at.
Parameter
DC Breakdown on Data Lines
DC Breakdown - Power Lines
Power Rating
Line Series Resistance (Loop)
Line Series Balance
Capacitance Line to Line @ 1 MHz
BER Performance Testing
10/100/1000 Mbps
Surge Response Time
Surge Withstand Capability (Imax) @ 8/20 μs
Surge Limiting Performance
Let-Through Voltage
Let-Through Current
First Level Surge
1 kV – 10/1000 μs, 100 A
2.5 kV – 2/10 μs, 500 A
800 V – 1.2/50 μs, 8/20 μs Combo Wave
Second Level Surge
2.5 kV – 2/10 μs, 500 A, Inductive Kick
6 kV / 3 kA – 1.2/50 μs, 8/20 μs
Combo – 10/1000 μs, 100 A
First Level Power Fault
220 mA Below Protection Threshold
600 V / 1 A / 1 Second
1000 V / 1 A / 1 Second
425 V / 0.5 A / 4 Seconds
Second Level Power Fault
120 V / 25 A 1
425 V / 40 A / 1.5 Second 1
425 V / 7 A / 5 Seconds 1
425 V / 2.2 A
Storage and Effective Temperature
UL Flame Rating
Ingress Protection Ratings
Notes:
UL Listed component, UL File E153537
1) Fuse may fail open and disconnect from circuit.
Commercial Model 1530-1
150 V Typical Input / 7 V Typical Output
< 200 V Typ.
35 W
~ 6 Ω Typ.
0.5 Ω Typ. / 1.0 Ω Max
10 pF Typ.
> 100 meters
< 1 μs
10 kA
< 60 V
< 1A
> 10 operations
> 10 operations
> 10 operations
> 1 operation
> 1 operation
> 10 operations
15 minutes
> 60 operations
> 60 operations
> 1 operation
15 minutes
1 operation
1 operation
15 minutes
-40 to +65 °C
94 V0
20
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.