English
Language : 

1210 Datasheet, PDF (1/3 Pages) Frontier Electronics. – RF Coated Chokes (Axial Leads)
*RoHS COMPLIANT
Features
■ 100 kA max. discharge current rating
■ Multi-pole uni-block design
■ DIN Rail mountable
■ UL 60691 compliant integrated thermal
disconnect
■ Visual fault indicator
■ Remote signalling capability
■ Compact design ideal for limited spaces
■ Standards compliance:
■ RoHS compliant*
1210 Series Heavy Duty AC Surge Protective Device
General Information
The Bourns® Model 1210 Series is a heavy duty Surge Protective Device (SPD)
designed to protect high risk electrical service entrance and branch panels. This SPD is
intended to be installed at the front end of the installation, in the main switchboard, close
to sensitive terminals or in installations without LPS (lightning rods).
The Model 1210 Series is a single-pole module that can be configured for both common
mode and differential mode protection in single and three phase applications up to 600 V.
Electrical Diagram
L/N
...
C
Ft Ft
Mi
VV
V : High energy varistor
Ft : Thermal fuse
C : Remote signaling contact
t° : Thermal disconnection system
Mi : Disconnection indicator
Electrical Characteristics
Characteristic
AC Network
Connection Mode
AC System
Max. Operating Voltage (MCOV)
TOV Withstand
Leakage Current at Uc
Follow Current
UL Nominal Discharge Current (In)
15 Impulses 8/20 µs
Max. Discharge Current (Imax)
1 Impulse 8/20 µs
Max. Lightning Current (Iimp)
1 Impulse 10/350 µs
UL Voltage Protection Rating (VPR)
Protection Level (Up)
UL Short-Circuit Current Rating (SCCR)
1210-xS-120
120/240 V,
120/208 V
150 V
150 V
600 V
0.9 kV
Model No.
1210-xS-230
1210-xS-400
220/380 V,
240/415 V
220/380 V,
277/480 V,
347/600 V
1-Pole, L-N or L-G
IT, TT, TN, Single, Split Phase, Delta, Wye
275 V
400 V
275 V
400 V
< 1 mA
None
20 kA
100 kA
900 V
1.25 kV
--
100kAIC
1200 V
1.8 kV
1210-xS-600
480 V,
600 V
840 V
840 V
3000 V
4.0 kV
General Characteristics
Characteristic
Thermal Disconnector
Overcurrent Protection
Connection
Dimensions
Mounting
Remote Signal Indicator
Enclosure Material
1210-xS-120
Model No.
1210-xS-230
1210-xS-400
UL 60691
Time Delay - 125 A Max.
By Screw Terminals, #6 AWG Max.
90 x 18 x 67 mm / (3.543 x 0.709 x 2.638 In.)
DIN Rail, 35 mm Symmetrical
250 V Max., 2 A
Thermoplastic UL 94V0
1210-xS-600
Environmental Characteristics
Characteristic
Operating Temperature
Operating Altitude
Relative Humidity
Environmental Rating
1210-xS-120
Model No.
1210-xS-230
1210-xS-400
-50 °C to +85 °C
13,000 ft. (4,000 m)
5 to 95 % Non-condensing, up to 100 % External
IP 20
1210-xS-600
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.