English
Language : 

BUB20-SERIES Datasheet, PDF (5/7 Pages) Bothhand USA, LP. – Isolated DC-DC Converters
Bothhand USA
Specifications subject to change without noticed.
Isolated DC-DC Converters
BUB20 Series -- 20 Watt
Test Configurations
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
A
DC
Power Supply
V
DC/DC
converter
A
V
Load
◎DC Power Supply: It offers a wide voltage and current range precisely.
◎Current meter (A): Accuracy 200μA ~ 200mA 4 ranges+(0.2% rdg + 2 digits)
2000mA ~ 20A 2 ranges+(0.3% rdg + 2 digits).
◎Voltage meter (V): Accuracy +(0.03% rdg + 4 digits).
◎Load: At full load.
◎Wires: The resistance of the wires must be small.
1. Input voltage range: Narrow input voltage range(±10%)、wide input voltage range (2:1 and 4:1)。
EX: Narrow input voltage range(±10%)
5V nominal input
4.5~5.5V
12V nominal input
10.8~13.2V
24V nominal input
21.6~26.4V
Wide input voltage range 2:1
5V nominal input
12V nominal input
24V nominal input
48V nominal input
4.5~9V
9~18V
18~36V
36~75V
Wide input voltage range 4:1 (W)
24V nominal input
9~36V
48V nominal input
18~75V
2. Input power :
Pin = Vin x Iin
Vin:Input voltage
Iin:Input current
3. Output power :
Pout = Vout x Iout
Vout:Output voltage
Iout:Output current
4. Efficiency :
Efficiency = Pout x100%
Pin
Pout: Output power
Pin: Input power
5. Voltage accuracy:
│Vout-Vout(nominal)│
Vout
x100%
Vout:Output voltage
Vout(nominal):Nominal output voltage
sales@bothhandusa.com
www.bothhandusa.com
Rev:20130814 A
Page 5 of 7