English
Language : 

BYB100 Datasheet, PDF (2/8 Pages) Bothhand USA, LP. – Isolated DC-DC Converters
BOTHHAND USA
PRELIMINARY
Isolated DC-DC Converters
BYB100 Series -- 100Watt
Input Specifications
Input voltage
Input filter
Input surge voltage (100ms max.)
Input reflected ripple current
Start up time
Remote ON/OFF
Sourcing current of remote control pin
Idle input current (at Remote OFF state)
Environmental Specifications
Operating ambient temperature
Maximum case temperature
Storage temperature range
Relative humidity
Temperature coefficient
Output Specifications
Output power
Voltage accuracy
Minimum load
Line regulation
Load Regulation
Ripple and Noise (20MHz Bandwidth)
Over voltage protection
(Zener Diode Clamp)
Capacitive load
Over load protection
Thermal shutdown
Short circuit protection
Transient response settling time
Transient response over shoot
48V nominal Vin
48V nominal Vin
Nominal Vin and full load
Nominal Vin and constant resistive load
Converter: ON
Converter: OFF
Nominal Vin
Nominal Vin
Full load and nominal Vin
LL to HL at full load
25% load to full load
12Vout
(Measured with a 2.2uF/50V MLCC)
24Vout and 28Vout
(Measured with a 10uF/50V MLCC)
48Vout
(Measured with a 2.2uF/100V MLCC)
12Vout
24Vout
28Vout
48Vout
% of full load at nominal input
50% load step change
di/dt=0.8A/µs
36-75V
Pi type
100V
600mAp-p typ.
68ms typ.
Open or 3.5VІVrІ12V
Short (3) or 0VІVrІ0.7V
І0.2 mA
І20 mA
-40°C to +85°C (with derating)
+105°C
-40°C to +105°C
95% RH max.
±0.02% / °C max.
100 Watts max.
±1%
0mA
±1%
±1%
100mVp-p max.
200mVp-p max.
300mVp-p max.
15V
33V
36V
58V
See table
110% min.
110°C typ.
Hiccup, automatic recovery
480µs typ.
≤ ±5% of Vo
E-mail: sales@bothhandusa.com
http://www.bothhandusa.com
Rev:20150720A