English
Language : 

BXC60-24S2WHS Datasheet, PDF (1/4 Pages) Bothhand USA, LP. – Isolated DC-DC Converters
BOTHHAND USA
Features
Isolated DC-DC Converters
BXC60-24S2WHS
Wide 4 : 1 Input Voltage Range
High Power Density
High Efficiency
Operating Temperature Range: -40°C to +85°C
Output Short Circuit Protection:
Hiccup, continuous & Auto Recovery
Output Over Voltage Protection:
Over Temperature Protection
Fixed Switching Frequency
Input/ Output Isolation 1.5 kVdc
Shielded Metal Case with Insulated Baseplate
Lead Free Design, RoHS Compliant
Industry Standard Pinout
Adjustable Output Voltage
Applications
Distributed power system
Telecommunication application
Battery powered equipment
Industrial application
Process control equipment
Transportation equipment
Input Specifications
Input voltage range
Under voltage shutdown
Input current
Input current
Input current
Remote ON/OFF
Sourcing current of remote control pin
Idle input current (at Remote OFF state)
Output Specifications
Output voltage
Output voltage accuracy
Maximum Load
Minimum Load
Maximum capacitive load
Efficiency
Ripple / Noise
Temperature coefficient
Output short circuit protection
Output over voltage protection
Full Load
Vin=24Vdc and no Load
Vin=24Vdc and full Load
Vin=24Vdc and output shorted
Converter: ON
Converter: OFF
Nominal Vin
Nominal Vin
Vout=11.88 ~ 12.12Vdc
Vin=24Vdc and full load
20MHz bandwidth.
Automatic recovery
E-mail: sales@bothhandusa.com
http://www.bothhandusa.com
9~36Vdc
8Vdc (typical)
100mA (typical)
2976mA (typical)
10mA (typical)
Open or 3.5V<Vr<12V
Short(2) or 0V<Vr<0.7V
<0.2mA
<12mA
12 Vdc
±1%
5A
0A
4700uF (maximum)
88% (typical)
80mVp-p (maximum)
±0.02%/℃ (maximum)
Hiccup, Continuous
15V (typical)
Rev:20110610A
Page 1 of 4