English
Language : 

BUA10-110S15R3 Datasheet, PDF (1/3 Pages) Bothhand USA, LP. – Isolated DC-DC Converters
Bothhand USA
Features
Wide Input Voltage Range ( 66 ~ 160Vdc )
High Power Density
High Efficiency
Operating Temperature Range: -40°C to +85°C
Output Short Circuit Protection
Output Over Voltage Protection
Fixed Switching Frequency
Input/ Output Isolation 1.5 KVdc
Shielded Metal Case with Insulated Baseplate
Lead Free Design, RoHS Compliant
Industry Standard Pinout
Customer Design Available
Isolated DC-DC Converters
BUA10-110S15R3
Applications
● Distributed power system
● Telecommunication application
● Battery powered equipment
● Industrial application
● Process Control equipment
● Transportation equipment
Input Specifications
Input voltage range
Under voltage shutdown
Input current
Input current
Input current
Output Specifications
Output voltage
Output voltage accuracy
Maximum Load
Minimum Load
Maximum capacitive load
Efficiency
Ripple / Noise
Temperature coefficient
Output short circuit protection
Output over voltage protection
Line regulation
Load regulation
www.bothhandusa.com
Full Load
Vin=110Vdc and no Load
Vin=110Vdc and full Load
Vin=110Vdc and output shorted
Vout=15.147 ~ 15.453Vdc
Vin=110Vdc and full load
20MHz bandwidth.
Automatic recovery
LL to HL at full load
25% load to full load
66~166Vdc
59Vdc(typical)
6mA(typical)
116mA(typical)
10mA(typical)
15.3Vdc
±1%
670mA
0mA
330uF(maximum)
84%(typical)
100mVp-p (maximum)
±0.02%/℃(maximum)
Continuous
18V(typical)
±0.5%(maximum)
±1%(maximum)
sales@bothhandusa.com
Rev:20100903A
Page 1 of 3