English
Language : 

ARI-6400F Datasheet, PDF (1/1 Pages) BOSER Technology Co., Ltd – 400W Redundant Power Supply
ARI-6400F
400W Redundant Power Supply
DC OUTPUT WIRES
16.8
16.0
3.5 9.0
2.1
13.4
Features
*Input Voltage: 90~132VAC or 180~260VAC selectable
*Input Frequency: 47~63Hz
*Input Current: 10A at 115VAC or 6A at 230VAC max.
*Inrush Current: < 50A at 100VAC, < 100A at 220VAC, < 60A
at 230VAC input cold start, 25oC excluding EMI capacitors
*Load Range: At 100% max. load condition in all outputs, +5V
output is between 4.98V and 5.02V, +3.3V is between +3.25V
and +3.35V. All other outputs are within their specified voltage
accuracy ranges
*Ripple and Noise: Peak to peak ripple and noise for +5V and
+3.3V outputs are < 60mV, and < 120mV for -5V, +12V, and
+5Vsb outputs
*Line Regulation: < +/-1% for +5V, +12V, -12V, and +5Vsb
outputs. +3.3V is +/-2%
*Hold Up Time: > 16ms at 115VAC or 230VAC input and max.
load measured from the last AC line charging pulse to the point
when +5V drops down to +4.75V
*Output Power: Total DC continuous power is within 400W at
< 30oC ambient temperature
*Power Good Signal: Signal goes high from 100~500ms after
all output DC voltages are within regulation limits
*Power Redundancy: This power supply has power redundant
capability
*Efficiency: 65% typical, measured at nominal line and rated
load
*Protection: Built-in over voltage protection circuit. Trip point
between 5.7~7.0V AC line off and on cycle for over voltage
protection recovery latch off mode against short circuit or over
load conditions
*Dimensions: 19.2 x 16.8 x 22.0 cm
Safety Standards
*Safety: UL 1950 / CSA 1402C & CSA 950 / TUV EN60950
*Earth Continuity Resistance: FG to HG > 0.01 ohm11
*EMI: FCC part 15 class B rules VDE
Output Min.
Voltage Load
+5V 7A
+12V 2.5A
-12V 0A
-5V 0A
+3.3V 3A
+5Vsb 0.1A
Rated
Load
25A
16A
0.8A
0.8A
20A
0.75A
Max.
Load
Voltage
Accuracy
36A 4.75~5.25V
17A 11.4~12.9V
0.8A -11.30~-12.6V
0.8A -4.65~-5.25V
25A 3.15~3.45V
2A
4.8~5.2V
www.boser.com.tw