Insulation and Safety Related Specifications
Parameter
Minimum External Air
Gap (Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
CTI
Value
>5
>5
0.08
>175
IIIa
Units
mm
mm
mm
V
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Insulation thickness between emitter and detector;
also known as distance through insulation.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0109)
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics
Description
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b†
VIORM x 1.875 = VPR, 100% Production
Test with tm = 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a†
VIORM x 1.6 = VPR, Type and Sample Test,
tm = 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage†
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
ACPL-M71T/
ACPL-M72T
567
1063
Units
VPEAK
VPEAK
907
VPEAK
6000
VPEAK
Ts
150
°C
Is, INPUT
150
mA
Ps,OUTPUT
600
mW
RIO
≥109
Ω
4