English
Language : 

HM69 Datasheet, PDF (1/3 Pages) Bi technologies – High Current Low Profile Surface Mount Inductors
Electrical / Environmental

RCoomHpliSant
High Current Low Profile Surface Mount Inductors
• Operating Temperature Range
• Temperature Rise, Maximum
• Ambient Temperature, Maximum
• Insulation System
-40°C to +125°C
40°C
80°C
Class F, 155°C
Specifications
Part
Number
Inductance
100kHz, 0.1V
@ 0 Adc
(nH±20%)
@ Irated
(nH)
Typ.
Min. Typ.
DCR (1)
(mΩ)
Typ. Max.
Irated (2)
@ 25°C
(Adc)
Heating
Current(3)
(A)
Core Loss (4)
Factor
K1
K2
HM69-10R025LF
HM69-20R050LF
HM69-30R070LF
HM69-40R10LF
HM69-50R10LF
HM69-50R15LF
HM69-55R10LF
HM69-55R20LF
HM69-60R10LF
HM69-60R15LF
HM69-60R20LF
HM69-70R30LF
HM69-75R20LF
HM69-80R30LF
25
18 25
50
28 36
70
50 67
100
60 75
100
72 95
150
96 120
100
64 80
200
140 175
100
69 87
150
104 130
200
144 180
300
200 250
200
150 175
300
216 285
0.27
0.33
42
0.20 0.24
70
0.40 0.48
46
0.31
0.39
28
0.40 0.48
29
0.40 0.48
18
0.45
0.56
45
0.45
0.56
21
0.42 0.50
68
0.42 0.50
48
0.42 0.50
31
0.17
0.20
37
0.40 0.50
20
0.17
0.25
40
22
3.847E-14 59.444
35
1.074E-13 50.117
25
1.074E-13 70.164
25
7.124E-14 156.891
24
8.733E-14 127.990
24
8.733E-14 191.986
25
1.337E-13 96.541
25
1.337E-13 160.902
31
2.311E-13 52.336
31
2.311E-13 78.503
31
2.311E-13 104.671
70
6.784E-13 98.921
40
3.559E-13 134.203
76
9.107E-13 72.674
Notes: (1) DC resistance is measured at 25°C.
(2) The rated current (Irated) is the current at which the inductance will be decreased by 20% from its initial (zero DC) value.
(3) The heating current is the DC current, which causes the component temperature to increase by approximately 40°C. This current is determined
by soldering the component on a typical application PCB, and then apply the device for 30 minutes.
(4) Core Loss approximation is based on published core data:
Core Loss = K1 * (f)1.77 * (K2∆I)2.21
Where: core loss in watt
f = switching frequency in kHz
K1 and K2 = core loss factor ∆I = delta I across the component in Amp.
K2∆I = one half of the peak to peak flux density across the component in Gauss
Packaging
Standard: Embossed Tape & Reel
Reel:
Diameter:
Capacity: Case size 10,40
Case size 20,30,60
Case size 50,55,75
Case size 70,80
= 13” (330.2mm)
=
1000 Units
=
800 Units
=
500 Units
=
350 Units
Ordering Information
Model Series
HM69 50 R10 LF TR13
Case Size
Lead-Free
Inductance Code:
First 2 digits are significant.
Last digit denotes the number of trailing zeros.
For values below 10µH, “R” denotes the decimal point.
TR - Tape & Reel Packing
13 - 13” reel
60 MAGNETIC COMPONENTS SELECTOR GUIDE 2007/08 EDITION
We reserve the right to change specifications without prior notice.
www.bitechnologies.com