English
Language : 

MBC275-1T12L Datasheet, PDF (3/7 Pages) Bel Fuse Inc. – 5 x 3 x 0.75 Inches Form factor
MBC275 Series
3
Output Power2
Efficiency (typical @ 230 VAC full load)
Hold-up Time
Line Regulation
Load Regulation
Transient Response
Voltage Adjustment
Rise Time
Set Point Tolerance3
Over Current Protection
Over Voltage Protection
Short Circuit Protection
With 13 CFM forced air cooling
With natural convection cooling at 100 to 264 VAC
48 V, 58 V:
24 V, 30 V:
12 V, 15 V:
At 275 W:
At 160 W:
25% step load change, at 0.1 A/uS slew rate, 50% duty
cycle, 50 Hz = 4%
Typical
Hiccup mode
275 W
up to 160 W
92%
90%
88%
8 ms
16 ms
+/-0.5%
+/-1%
recovery time < 5 ms
+/-3%
55 ms
+/-1%
> 110%
110 to 140%
2 Combined output power of main output, fan supply shall not exceed max. Power rating.
3 Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-10% and Ripple and noise is less than 10%.
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
MTBF
Startup guaranteed with spec. deviation
Non-condensing
Operating:
Non-operating:
Telcordia -SR332-issue 3
-40 to +70°C
-40 to 0°C
-40 to +85°C
5% to 95%
16,000 ft
40,000 ft.
3.37 million hours
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Radiated Emissions
Surge Susceptibility
Harmonic Current
EN55022-B, CISPR22-B, FCC PART15 – B
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
Radiated:
Radiated with external core:
(King core K5B RC 25x12x15-M in input cable (5 turns))
EN61000-4-5:
EN61000-3-2:
Level-3
Level-3
Level-3
Level A
Level B
Level-3
Class D
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2016 Bel Power Solutions & Protection
North America
+1 408 785 5200
BCD.00882_001